Graft dislocation following Descemet stripping automated endothelial keratoplasty: a comparative cohort analysis of Optisol GS and organ culture preserved corneas.

Cell Tissue Bank

Department of Ophthalmology and Visual Sciences, Dalhousie University, 1276 South Park Street, Room 2035D, 2 West Victoria Building, Halifax, NS, B3H 2Y9, Canada.

Published: June 2023

Previous studies have suggested risk factors for graft dislocation after Descemet stripping automated endothelial keratoplasty (DSAEK). We aimed to investigate the influence of eye bank storage solution as a risk factor for graft dislocation, as this could have significant implications for eye banking practices. This retrospective analysis compared cohorts from the QEII Health Sciences Center, Halifax, Canada (donor corneas preserved in Optisol GS) and the Royal Victorian Eye and Ear Hospital, Melbourne, Australia (donor corneas preserved in organ culture). Patient, surgical, and post-operative data were collected for consecutive DSAEK surgeries performed between 2012 and 2020. Risk factors were analyzed using univariate and multivariate logistic regression modeling. 654 DSAEK surgeries were performed during the study period: 271 in the Optisol GS storage cohort and 383 in the organ culture cohort. The most common indications were pseudophakic bullous keratopathy, Fuchs endothelial dystrophy, and failed previous DSAEK. The incidence of graft dislocation requiring surgical repositioning was 9.6% (n = 26) in the Optisol GS cohort and 12.0% (n = 46) in the organ culture cohort (OR, 0.50, 95% CI, 0.20-1.13). Development of graft dislocation was associated with intraoperative venting incisions (OR, 2.50, 95% CI, 1.12-5.51) and a post-operative wound leak (OR, 55.24, 95% CI, 10.20-514.85). The incidence of DSAEK dislocation was similar between study sites using Optisol GS and organ culture, suggesting changes in eye bank storage solution would not mitigate this post-operative complication. Intraoperative creation of venting incisions and post-operative wound leaks and were factors associated with graft dislocation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10561-022-10050-4DOI Listing

Publication Analysis

Top Keywords

graft dislocation
24
organ culture
20
dislocation descemet
8
descemet stripping
8
stripping automated
8
automated endothelial
8
endothelial keratoplasty
8
optisol organ
8
risk factors
8
eye bank
8

Similar Publications

Background: The Latarjet procedure is considered the gold standard for treating patients with anterior shoulder instability in the presence of critical glenoid bone loss. Proponents of the Latarjet contend that its efficacy is in-part attributable to the "sling effect" of the conjoint tendon; however, recent studies have demonstrated similar restoration of anterior stability in patients undergoing free bone block (FBB) procedures. The purpose of this systematic review was to evaluate the biomechanical and clinical evidence for the sling effect.

View Article and Find Full Text PDF

Background: For patients with osteoporosis and rotator cuff tears, there is still no consensus on current treatment methods. The material, structure, and number of anchors have important effects on the repair outcome.

Purpose: To investigate the use of chitosan quaternary ammonium salt-coated nickel-titanium memory alloy (NTMA) anchors to treat rotator cuff injury in shoulders with osteoporosis in a rabbit osteoporosis model.

View Article and Find Full Text PDF

Application of additive manufacturing TaBw01 porous tantalum rod in ARCO stage II osteonecrosis of the femoral head.

J Orthop Surg Res

December 2024

Center for Joint Surgery, Southwest Hospital, Army Medical University, Gaotanyan Street, Shapingba District, Chongqing, 400038, China.

Purpose: This study aims to investigate the suitable surgical strategies for applying TaBw01 porous tantalum rod across different stages of osteonecrosis of the femoral head (ONFH).

Methods: TaBw01 tantalum rods were fabricated using type FTaY-1 tantalum powder via the foam impregnation-sintering method. Mechanical testing with the Instron 8801 universal testing machine and finite element analysis (FEA) assessed single tantalum rod implantation and impaction bone grafting combined with rod implantation.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the effectiveness of two types of bone grafts (packed cancellous vs. corticocancellous) used in repairing scaphoid waist nonunion fractures with volar locking plates.
  • Postoperative CT scans showed that 95% of patients achieved osseous bridging, but those with packed cancellous grafts had significantly better healing outcomes than those with corticocancellous grafts.
  • The findings suggest that using packed cancellous autografts may lead to faster and more effective bone healing in these cases.
View Article and Find Full Text PDF

The elbow is one of the most commonly dislocated joints. Although simple dislocations of the elbow usually resolve with conservative management, certain patients can experience residual chronic instability. Posterolateral rotational instability accounts for approximately 80% of elbow chronic instability cases.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!