Strain sensing technology using fibre Bragg grating (FBG) sensors is an attractive capability for aerospace structural health monitoring (SHM) and assessment because they offer resistance to harsh environments, low maintenance, and potential for high density and high strain sensing. The development of FBG inscription techniques through the fibre polymer coating using infrared (IR) lasers has overcome the mechanical weaknesses introduced by removal of the fibre coating, which is typically required for conventional UV laser inscription of FBGs. Type I and Type II femtosecond gratings are fabricated using through-coating inscription techniques, but the higher laser energy used for Type II gratings damages the glass fibre core, impacting mechanical performance. This paper investigates the fatigue performance of Type I and Type II through-coating FBG sensors with different fibre geometries and photosensitisation approaches to evaluate their overall reliability and durability, with a view to assess their performance for potential use in civil and defence SHM applications. The fatigue performance of FBG sensors was assessed under high-strain and high-frequency mechanical loading conditions by using a custom-designed electro-dynamically actuated loading assembly. In addition, pre- and post-fatigue microscopic analyses and high-resolution reflection spectrum characterisation were conducted to investigate the failure regions of the fibres and the effect of fatigue loading on reflection spectrum features. As expected, Type I gratings had a significantly higher fatigue life compared to Type II gratings. However, Type II gratings performed significantly better than conventional UV laser-inscribed FBGs and electrical foil strain gauges. Type II gratings withstand higher temperatures, and are therefore more suitable for application in harsh environments.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9696806PMC
http://dx.doi.org/10.3390/s22228812DOI Listing

Publication Analysis

Top Keywords

type gratings
20
fatigue performance
12
type type
12
fbg sensors
12
type
11
performance type
8
fibre bragg
8
gratings fabricated
8
laser inscription
8
strain sensing
8

Similar Publications

Smart concrete is a structural element that can combine both sensing and structural capabilities. In addition, smart concrete can monitor the curing of concrete, positively impacting design and construction approaches. In concrete, if the curing process is not well developed, the structural element may develop cracks in this early stage due to shrinkage, decreasing structural mechanical strength.

View Article and Find Full Text PDF

An objective soft x-ray flat-field spectrograph employing a laminar-type bilayer coated, varied-line-spacing, spherical grating was designed to improve the detection limit and sensitivity of soft x-ray flat-field spectrographs in a region of 250-550 eV. As a design criterion, spectral flux, SF, [Hatano et al., Appl.

View Article and Find Full Text PDF

Gamma rhythm (30-70 Hz), thought to represent the interactions between excitatory and inhibitory populations, can be induced by presenting achromatic gratings in the primary visual cortex (V1) and is sensitive to stimulus properties such as size and contrast. In addition, gamma occurs in short bursts, and shows a "frequency-falloff" effect where its peak frequency is high after stimulus onset and slowly decreases to a steady state. Recently, these size-contrast properties and temporal characteristics were replicated in a self-oscillating Wilson-Cowan (WC) model operating as an Inhibition stabilized network (ISN), stimulated by Ornstein-Uhlenbeck (OU)-type inputs.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the stability and safety of faricimab, an anti-VEGF biologic, when compounded into two types of polypropylene syringes and stored for 28 days.
  • No significant differences in binding affinity for VEGF and Ang-2 were observed between the syringe types, and the compound maintained its chemical and physical stability, sterility, and lack of bacterial endotoxins.
  • These results support the safe off-label use of faricimab, potentially reducing costs while ensuring patient safety in clinical practice.
View Article and Find Full Text PDF

Metallic gratings can be used as infrared filters, but their performance is often limited by bandwidth restrictions due to metallic losses. In this work, we propose a metallic groove-slit-groove (GSG) structure that overcomes these limitations by exhibiting a large bandwidth, angularly independent, extraordinary optical transmission. Our design achieves high transmission efficiency in the longwave infrared range, driven by Fano-type resonances created through the interaction between the grooves and the central slit.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!