AI Article Synopsis

  • The paper examines how temperature affects the rheological properties of magnetorheological (MR) gel through rotational and oscillatory shear tests, focusing on the yield and normal stress.* -
  • An MR gel was created by combining carbonyl iron powder with a polymer, revealing that as temperature increases, the maximum yield stress decreases, while the relationship between shear and normal stress varies with temperature.* -
  • Under magnetic conditions, the gel’s storage and loss moduli increase with temperature; however, the trends reverse without the magnetic field, leading to insights about the microstructural changes in the MR gel.*

Article Abstract

In this paper, the effect of temperature on rheological properties of magnetorheological (MR) gel is investigated under rotational steady shear and oscillatory dynamic shear. A kind of fluid-like MR gel (MRG) was firstly synthesized by mixing carbonyl iron powder (CIP) with polymer matrix. Then, the relationship between yield stress, normal stress of MRG and shear rate under six temperatures and four magnetic field strengths were studied by rotational shear experiments. The results demonstrate that the dependence of shear stress on temperature displays an opposite tendency in comparison with that of normal stress on temperature. Moreover, maximum yield stress, one of the most important parameter of MR materials, decreases with the increment of temperature. Under oscillatory dynamic shear test, storage and loss moduli and normal stress of MRG all increase with temperature when a magnetic field is applied, which presents a contrary trend in the absence of a magnetic field. Related mechanisms about the alternation of microstructures of MRG were proposed to explain the above-mentioned phenomena. This paper is helpful in fabricating semi-active engineering devices using MR materials as a medium.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9699203PMC
http://dx.doi.org/10.3390/ma15228070DOI Listing

Publication Analysis

Top Keywords

magnetic field
16
normal stress
12
temperature rheological
8
magnetorheological gel
8
oscillatory dynamic
8
dynamic shear
8
yield stress
8
stress mrg
8
stress temperature
8
temperature
6

Similar Publications

Choroid plexus cysts on 7T MRI: Relationship to aging and neurodegenerative diseases.

Alzheimers Dement

December 2024

7T Magnetic Resonance Imaging Translational Medical Center, Department of Radiology, Southwest Hospital, Third Military Medical University (Army Medical University), Chongqing, China.

Introduction: The choroid plexus (CP) may play a crucial role in brain degeneration. We aim to assess whether CP cysts (CPCs), defined using ultra-high field magnetic resonance imaging (MRI), relate to aging and neurodegeneration.

Methods: We used multi-sequence 7T MRI to observe CPCs, characterizing their presence and characteristics in healthy younger controls, healthy older controls (OCs), patients with Alzheimer's disease (AD), patients with Parkinson's disease (PD), and patients with uremic encephalopathy.

View Article and Find Full Text PDF

Objectives: Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive neurostimulation technique that uses magnetic field to comprehensively influence events in the brain. Its use in patients after stroke focuses mainly on influencing brain neuroplasticity and therefore has the potential to improve motor functions in these patients. This study investigates the effect of rTMS on motor function recovery in patients in the acute stage of ischemic stroke.

View Article and Find Full Text PDF

In this study, a novel acid-induced heat-set soy protein hydrolysate (SPH) gel was successfully developed. The effects of protein (7 and 8 wt%) and glucono-δ-lactone (GDL, 4, 6, 8, and 10 wt%) concentrations on its aggregation and gelation behaviors were investigated by evaluating the structural, rheological, textural, and physical properties of the SPH gel. The structural properties revealed that GDL promoted the formation of SPH aggregates and gels, primarily via disulfide bonds and hydrophobic interactions, which were closely related to the unfolding of the protein structure, exposed hydrophobic groups, decreased protein solubility, and increased particle size and turbidity during the heating process.

View Article and Find Full Text PDF

Magnetic Resonance Imaging (MRI) is a sophisticated diagnostic tool that utilizes the magnetic properties of biological tissue to generate detailed images of internal structures without the use of ionizing radiation. Despite its benefits in providing high-contrast images of soft tissues, the strong magnetic fields used in MRI present a unique safety challenge. Increasing MRI-related accidents and the prevalence of patients with metallic implants in recent years underscore the critical need for stringent MR safety protocols.

View Article and Find Full Text PDF

Introduction: Tumorous growths in the sellar region pose significant clinical challenges due to their proximity to critical visual structures such as the optic chiasm and optic nerves. Given their proximity to the optic system, these tumors are often diagnosed due to a progressive decrease in visual acuity. Thus, surgical intervention is crucial to prevent irreversible damage, as timely decompression can halt the progression of edema and subsequent optic atrophy.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!