Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Monitoring core temperature is crucial for maintaining normothermia during general anesthesia. Insertion of a gastric decompression tube (GDT) may be required during laparoscopic surgery. Recently, a newly designed GDT with a thermistor for monitoring esophageal temperature has been introduced. The purpose of the present study was to evaluate the optimal insertion depth of a GDT with a thermistor. Forty-eight patients undergoing elective laparoscopic surgery in the Trendelenburg position were included in the study. The GDT was inserted to a depth of nose-earlobe-xiphoid distance (NEX) + 12 cm and withdrawn sequentially, 2 cm at a time, at 5-min intervals. Temperatures of the GDT thermistor were compared with the core temperature of the tympanic membrane (TM) using Bland and Altman analysis. The correlation between optimal insertion depth of the GDT and anatomical distance (cricoid cartilage to the carina, CCD; carina to the left hemidiaphragm, CLHD) was evaluated, and a mathematical model to predict the optimal insertion depth of the GDT with a thermistor was calculated. Temperatures of TM and GDT thermistor at NEX + 4 cm showed good agreement and strong correlation, but better agreement and stronger correlation were seen at the actual location with the most minor temperature differences. The optimal insertion depth of the GDT was estimated as -15.524 + 0.414 × CCD - 0.145 × CLHD and showed a strong correlation with the actual GDT insertion depth (correlation coefficient 0.797, adjusted R = 0.636). The mathematical formula using CCD and CLHD would be helpful in determining the optimal insertion depth of a GDT with a thermistor.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9690127 | PMC |
http://dx.doi.org/10.3390/ijerph192214708 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!