Objectives: Verifying the clinical effectiveness and the impact on quality-of-life parameters, fear of hypoglycaemia and satisfaction with the treatment obtained with a flash glucose monitoring (MFG) devices implantation program that includes a telematic and group educational intervention in adults with type 1 diabetes.

Patients And Methods: Prospective quasi-experimental study, carried out during the COVID-19 pandemic period with a 9-month follow-up at the Virgen Macarena University Hospital, Sevilla.

Results: Eighty-eight participants were included (men: 46.6%; mean age (years) 38.08, SD: 9.38); years of DM1 evolution: 18.4 (SD: 10.49); treatment with multiple doses insulin (MDI) 70.5% vs 29.5% subcutaneous insulin infusion therapy (CSII)). Baseline HbA1c was 7.74% (1.08). After the intervention, the global decrease in HbA1c was -0.45% (95% CI [-0.6, -0.25], P < 0.01), increasing to -1.08% in the group that started with HbA1c ≥ 8% (P < 0.01). A mean decrease in the Fear of Hypoglycemia 15 (FH15) test score of -6.5 points was observed (P < 0.01). In the global score of the Spanish version of Diabetes Quality Of Life (DQOL-s) test, the decrease was -8.44 points (P < 0.01). In Diabetes Treatment Satisfaction Questionnaire test (DTQ-s), global score increased in + 4 points (P < 0.01).

Conclusions: The incorporation of an educational program in group and telematic format within the development of MFG devices implantation strategies is an effective option, with associated benefits in quality of life and fear of hypoglycemia in adult patients with DM1. This option can be implemented in usual clinical practice.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.endien.2022.11.002DOI Listing

Publication Analysis

Top Keywords

flash glucose
8
glucose monitoring
8
educational intervention
8
intervention adults
8
adults type
8
effectiveness flash
4
monitoring systems
4
systems implementation
4
implementation program
4
program group
4

Similar Publications

Accuracy and feasibility of continuous glucose monitoring system in pancreatectomy patients.

Langenbecks Arch Surg

January 2025

Department of Surgery, Division of HBP Surgery & Liver Transplantation, Korea University College of Medicine, Seoul, Korea.

Purpose: Pancreatectomy patients often experience challenging fluctuations in blood glucose levels; therefore, they require a reliable monitoring system. This study aimed to determine the accuracy and acceptability of a continuous glucose monitoring (CGM) system compared with the intermittent capillary glucose test in patients who have undergone pancreatectomy.

Methods: Thirty non-diabetic pancreatectomy patients participated.

View Article and Find Full Text PDF

Intermittent Use of Flash Glucose Monitoring Improves Glycemic Control in Chinese Older Patients with Type 2 Diabetes Mellitus.

Diabetes Metab Syndr Obes

January 2025

Department of Endocrinology, Nanjing First Hospital, Nanjing Medical University, Nanjing, Jiangsu, 210012, People's Republic of China.

Objective: To explore the efficacy and safety of intermittent use of flash glucose monitoring (FGM) for improving glycemic control in Chinese elderly patients with type 2 diabetes mellitus (T2DM).

Methods: This is a prospective observational study involving patients with T2DM aged ≥60 years. The study period spans 12 weeks, with participants wearing FGM at weeks 0, 5, and 10.

View Article and Find Full Text PDF

Aims: This study assessed efficacy and safety of the fixed ratio combination iGlarLixi 100/33 (insulin glargine 100 U/mL plus lixisenatide 33 μg/mL) in people with type 2 diabetes (PwT2D) in daily clinical practice.

Materials And Methods: This non-interventional, multicentre, prospective, single-arm 24-week study documented PwT2D with an HbA1c of 7.5%-10.

View Article and Find Full Text PDF

Objective: This study compares ambulatory glycemic profile and glycemic variability between pregnant women diagnosed with type 2 diabetes mellitus (T2DM) receiving pharmacotherapy and healthy pregnant women without diabetes and assesses their correlation with fetal outcome.

Method: This was a case-control study involving 60 pregnant women (40 with T2DM and 20 healthy controls) in the third trimester of pregnancy. A flash glucose monitor device was applied over the upper arm to obtain the ambulatory glucose profile.

View Article and Find Full Text PDF

Young-onset diabetes (YOD) is characterised by unique diagnostic and management challenges more pronounced in resource-limited settings like Sri Lanka. We aimed to ascertain the prevalence, patterns and characteristics of YOD in Sri Lanka and describe the state of care. Retrospective review of baseline data of all patients enrolled in the prospective multicentre Database for Young-Onset Diabetes, Sri Lanka (DYOD-SL), was performed, from April 2021 to April 2023.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!