Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: The history of levothyroxine has been linked to advances in the treatment of thyroid disease and to date it is the standard therapy for the treatment of hypothyroidism. Bioequivalence studies are the most widely used method to demonstrate interchangeability, although controversy persists regarding the best design for this molecule declared as a narrow therapeutic index product in many countries. This study aimed to evaluate the pharmacokinetic profile of two formulations of levothyroxine to determine bioequivalence between them.
Methods: This two-period, randomized, crossover, blind study was conducted in 80 healthy volunteers, of both sexes, using a single levothyroxine dose of 600 μg with a washout period of 42 days. Blood sampling was performed at - 30 min, - 15 min, and 0 h pre-dose and 30 min, 1, 1.5, 2, 2.5, 3, 4, 6, 8, 10, 12, 16, 24, and 48 h post-dose.
Results: A total of 78 subjects successfully completed both periods. There were no serious adverse events during the study and both formulations were well tolerated. Baseline correction of serum levothyroxine concentrations was performed before statistical analysis. The mean maximum plasma concentration of the test product (Levotiroxina MK) was 57.49 ng/mL while for the reference product it reached 59.32 ng/mL. Importantly, both test and reference formulations reached maximum concentrations in plasma at about the same time. The areas under the pharmacokinetic curves with the test product showed AUC of 1407.1 ng h/mL and the reference product 1394.3 ng h/mL. The bioequivalence statistical analysis showed that the 90% confidence interval (CI) of the ratio of test over reference formulation was within the bioequivalence margins of 90-111%. For C, the test/reference ratio was 96.2% with CI of 91.6-100.9%, and for AUC the test/reference ratio was 99.9 with CI of 93.3-107.0%.
Conclusions: Both formulations have the same pharmacokinetic profile and are bioequivalent in the narrow therapeutic index required by some health authorities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10070282 | PMC |
http://dx.doi.org/10.1007/s12325-022-02352-6 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!