Upper limb control depends on accurate internal models of limb position relative to the head and neck, accurate sensory inputs, and accurate cortical processing. Transient alterations in neck afferent feedback induced by muscle vibration may impact upper limb proprioception. This research aimed to determine the effects of neck muscle vibration on upper limb proprioception using a novel elbow repositioning task (ERT). 26 right-handed participants aged 22.21 ± 2.64 performed the ERT consisting of three target angles between 80−90° (T1), 90−100° (T2) and 100−110° (T3). Controls (CONT) (n = 13, 6F) received 10 min of rest and the vibration group (VIB) (n = 13, 6F) received 10 min of 60 Hz vibration over the right sternocleidomastoid and left cervical extensor muscles. Task performance was reassessed following experimental manipulation. Significant time by group interactions occurred for T1: (F1,24 = 25.330, p < 0.001, ηp2 = 0.513) where CONT improved by 26.08% and VIB worsened by 134.27%, T2: (F1,24 = 16.157, p < 0.001, ηp2 = 0.402) where CONT improved by 20.39% and VIB worsened by 109.54%, and T3: (F1,24 = 21.923, p < 0.001, ηp2 = 0.447) where CONT improved by 37.11% and VIB worsened by 54.39%. Improvements in repositioning accuracy indicates improved proprioceptive ability with practice in controls. Decreased accuracy following vibration suggests that vibration altered proprioceptive inputs used to construct body schema, leading to inaccurate joint position sense and the observed changes in elbow repositioning accuracy.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9688255 | PMC |
http://dx.doi.org/10.3390/brainsci12111532 | DOI Listing |
Sensors (Basel)
January 2025
Faculty of Sport and Health Sciences, University of Jyväskylä, 40014 Jyväskylä, Finland.
Previous studies on the effects of intensified training on sleep quality/quantity have been somewhat contradictory. Moreover, recreational athletes often track various sleep metrics, and those metrics' actual connections to training adaptations are unknown. This study explored the effects of intensified training on sleep and nightly recovery along with their associations with training adaptations.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Curtin School of Allied Health, Curtin University, Perth 6102, Australia.
In hospitals, timely interventions can prevent avoidable clinical deterioration. Early recognition of deterioration is vital to stopping further decline. Measuring the way patients position themselves in bed and change their positions may signal when further assessment is necessary.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Division of Robotics, Swinburne University of Technology, Hawthorn, VIC 3122, Australia.
Wearable motion capture gloves enable the precise analysis of hand and finger movements for a variety of uses, including robotic surgery, rehabilitation, and most commonly, virtual augmentation. However, many motion capture gloves restrict natural hand movement with a closed-palm design, including fabric over the palm and fingers. In order to alleviate slippage, improve comfort, reduce sizing issues, and eliminate movement restrictions, this paper presents a new low-cost data glove with an innovative open-palm and finger-free design.
View Article and Find Full Text PDFSensors (Basel)
January 2025
2Ai, School of Technology, IPCA, 4750-810 Barcelos, Portugal.
Virtual reality (VR) has gained significant attention in various fields including healthcare and industrial applications. Within healthcare, an interesting application of VR can be found in the field of physiotherapy. The conventional methodology for rehabilitating upper limb lesions is often perceived as tedious and uncomfortable.
View Article and Find Full Text PDFSensors (Basel)
January 2025
Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.
(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!