Purpose: To evaluate the microtensile bond strength (µTBS) of three universal adhesives to dentin contaminated with a hemostatic agent.

Materials And Methods: Ninety-six human premolars were cut to expose mid-coronal dentin. The teeth were randomly divided into a control group (uncontaminated dentin) and an experimental group in which a hemostatic agent was applied (contaminated dentin). Each group was further divided into 6 subgroups according to universal adhesives - SBU (Single Bond Universal), OPU (OptiBond Universal), CBQ (Clearfil Universal Bond Quick) - and etching mode, either etch-and-rinse (ER) or self-etch (SE). Following adhesive application, composite was placed in two increments and light cured. The specimens were stored in distilled water at 37°C for 24 h. The µTBS test was performed using a universal testing machine. Failure mode was assessed using a light microscope. The data were statistically analyzed using three-way ANOVA followed by Scheffe's test (p < 0.05). The resin-dentin interface was observed using scanning electron microscopy.

Results: Significantly lower bond strength was observed when the universal adhesives were bonded to contaminated dentin in SE mode (p < 0.05). In contrast, the µTBS of the universal adhesives in ER mode was not affected by contamination (p > 0.05). The µTBS of CBQ to contaminated dentin was significantly lower than that of the other adhesives. Observation of the resin-dentin interface revealed limited resin penetration when the universal adhesive was applied in SE mode on contaminated dentin.

Conclusion: Contaminating the dentin with a hemostatic agent significantly reduced the µTBS of the universal adhesives in SE mode. However, this adverse effect was not found when the universal adhesives were used in ER mode.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11734302PMC
http://dx.doi.org/10.3290/j.jad.b3601769DOI Listing

Publication Analysis

Top Keywords

universal adhesives
28
universal
12
hemostatic agent
12
contaminated dentin
12
adhesives mode
12
adhesives
8
dentin
8
adhesives dentin
8
dentin contaminated
8
contaminated hemostatic
8

Similar Publications

Effect of Different Working Settings of Sandblasting on Resin Composite Repair Bond Strength.

Materials (Basel)

January 2025

Department of Preventive Dentistry, Periodontology and Cariology, University Medical Center Göttingen, 37075 Göttingen, Germany.

To investigate the effect of different sandblasting settings on the shear bond strength (SBS) in the repair of resin composite, specimens (resin composite, enamel, and dentin; each group = 16) were sandblasted by varying the parameters of air pressure (0.2/0.3/0.

View Article and Find Full Text PDF

Two 3D-printed crown materials (Crown and Ceramic Crown) were examined to determine the best surface treatment and primers for bonding. Discs of the two materials were printed and mounted with their "intaglio" surfaces untouched. Half the specimens from each group were sandblasted with 50 µm alumina.

View Article and Find Full Text PDF

ANTIMICROBIAL ACTION OF A MODIFIED UNIVERSAL ADHESIVE: AN IN VITRO STUDY.

Georgian Med News

November 2024

2Department of Conservative Dentistry, College of Dentistry, University of Mosul, Iraq.

Background: Resin composites and dental adhesives are widely used to restore carious teeth. A relatively new category of the dental adhesives, the universal adhesives (UAs) is considered user friendly because of its simplicity to use and compatibility with any adhesive strategy. However, the adhesive interface created by these adhesives is highly susceptible to cracking after polymerization which in turn facilitates the initiation of secondary caries.

View Article and Find Full Text PDF

The aim of this study is to evaluate the shear bond strength of different universal adhesives applied to intact, demineralized, and remineralized enamel surfaces with total-etch and self-etch modes and to examine the effect of universal adhesives on the Ca/P mineral atomic and mass ratios of these enamel with FE-SEM/EDX (Field Emission Scanning Electron Microscopy with Energy Dispersive X-Ray Spectroscopy) analysis. For this study, 264 bovine incisors were used. Samples in the demineralized and remineralized groups were kept in demineralization solution at 37 °C for 96 h to make an artificial initial carious lesion.

View Article and Find Full Text PDF

Background: Short dentin etching, a relatively recent technique, aims to improve resin-dentin bonding by preserving hydroxyapatite crystals within the collagen spaces. This study explores short dentin etching's potential in mitigating over-etching issues in deep proximal dentin/cementum margins, an aspect not previously investigated. This study evaluates the microtensile bond strength (μTBS) and marginal adaptation of two universal adhesives using different etch-and-rinse strategies (15-second and 3-second etching) and self-etch strategies, both immediate and post-thermal cycling and mechanical loading.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!