Objective: To investigate the therapeutic effect of lateral rectus abdominis incision combined with winged calcaneal plate on pelvic and acetabular fractures involving quadrilateral body.
Methods: From January 2017 to April 2021, 21 cases of pelvic and acetabular fractures involving quadrilateral bodies were retrospectively analyzed, including 12 males and 9 females. The age ranged from 21 to 73 years with an average of (43.23±6.45) years. All patients were treated by lateral incision of rectus abdominis combined with open reduction and internal fixation with aerofoil plate, including 12 cases of pelvis with anterior and posterior column fractures, 7 cases of acetabular fractures with quadrilateral involvement, and 2 cases of acetabular fractures with central dislocation.
Results: All 21 patients were followed up for 12 to 36 months with an average of (18.60±6.45) months. All fractures healed. According to Matta's image reduction evaluation after operation, 11 cases of pelvic anterior and posterior column fractures were all anatomic reduction, 1 case was satisfactory reduction, 7 cases of acetabular fractures involving quadrilateral were anatomic reduction, 1 case with central dislocation was anatomic reduction, and 1 case was satisfactory reduction. The modified Merle D'Aubigne Postel hip joint score was 13 to 17 points.
Conclusion: Lateral incision approach of rectus abdominis combined with wing-shaped steel plate can obtain good radiological and clinical results in the treatment of complex pelvic and acetabular fractures involving quadrilateral bodies, and has advantages in the treatment of complex pelvic fractures and acetabular quadrilateral fractures.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.12200/j.issn.1003-0034.2022.11.005 | DOI Listing |
Introduction And Importance: Neglected posterior hip dislocations in adults are rare, particularly when untreated for years. In developing nations, patients often rely on traditional bone setters, leading to delayed diagnosis and increased complications. Adult hip dislocations carry a higher risk of avascular necrosis and require complex treatments.
View Article and Find Full Text PDFFront Surg
December 2024
Department of Orthopedics, Jinjiang Municipal Hospital/Clinical Research Center for Orthopaedic Trauma and Reconstruction of Fujian Province, Jinjiang, Quanzhou, Fujian, China.
Objective: By comparing the hip arthroplasty parameters planned with the AIHIP three-dimensional simulation surgery system, this study analyzes the accuracy of the new femoral-side "shoulder-to-shoulder" artificial anatomical marker positioning method in femoral-side prosthesis implantation and the prevention of leg length discrepancy in hip arthroplasty.
Methods: A retrospective collection of 47 patients who underwent initial total hip arthroplasty at our hospital from August 2020 to December 2022 and met the inclusion and exclusion criteria was used as the study subjects. The average age was 67.
Expert Rev Med Devices
January 2025
Department of Orthopaedic Surgery, Kansai Medical University, Hirakata, Osaka, Japan.
Introduction: There is a worldwide trend toward 'revisiting' cemented total hip arthroplasty (THA). In Japan, however, cemented THAs accounts for 11%, and the percentage of cemented hemiarthroplasty is estimated to be less than 10%. This review was designed to reconsider the option of cemented THA and to encourage policy changes in Japan to support the best possible care for patients.
View Article and Find Full Text PDFPeriprosthetic fractures and their associated complications present significant challenges for orthopaedic surgeons. It is important to provide an overview of the current management of periprosthetic fractures, including techniques for osteosynthesis and revision total hip and knee arthroplasty, as well as special considerations for periprosthetic acetabular fractures, periprosthetic tibial fractures, and interprosthetic femur fractures. In addition, the guiding principles for the management of potential subsequent complications including infection, nonunion, and instability are discussed.
View Article and Find Full Text PDFBone Joint J
January 2025
Grampian Orthopaedics, Aberdeen Royal Infirmary, Aberdeen, UK.
Aims: The Exeter femoral stem has a cemented, polished taper-slip design, and an excellent track record. The current range includes short-length options for various offsets, but less is known about the performance of these stems. The aim of this study was to compare the survival of short-length stems with standard-length Exeter stems.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!