Background: The purpose of this study was to access the accuracy of cortical bone trajectory screw placement guided by spinous process clamp (SPC).

Methods: Eight formalin-treated cadaveric lumbar specimens with T12-S1 were used. A total of 96 screws were implanted in eight lumbar specimens.

Results: In the freehand (FH) group, clinically acceptable placement (grade A and B) was 40 screws (83.3%), meanwhile 44 screws (91.7%) in the SPC guide group (p = 0.217). The grade A screws in the SPC guide group were much more than that in the FH group (n = 40 vs. n = 31, p = 0.036). The misplacement screws (grade C, D, and E) and proximal facet joint violation (FJV) in the SPC group was comparable to the FH group.

Conclusions: This cadaveric study demonstrate that implanting CBT screws guided by SPC guide was more accuracy and reduces severe deviations in important directions.

Download full-text PDF

Source
http://dx.doi.org/10.1002/rcs.2484DOI Listing

Publication Analysis

Top Keywords

spc guide
12
accuracy cortical
8
cortical bone
8
bone trajectory
8
trajectory screw
8
guided spinous
8
spinous process
8
process clamp
8
grade screws
8
guide group
8

Similar Publications

Background: Short peripheral catheter (SPC) placement is a routine invasive procedure in clinical settings that is crucial for administering fluids, medications, or blood components. Approximately 11% of adult patients arriving at the Emergency Department (ED) experience difficulties with intravenous access (DIVA), necessitating advanced techniques for successful placement. The Enhanced Adult DIVA (EA-DIVA) score serves as a validated tool to promptly identify patients with DIVA.

View Article and Find Full Text PDF

The Strategic Plan for Cardiovascular Health in Portugal is an initiative of the Portuguese Society of Cardiology, aligned with efforts by the European Society of Cardiology and the World Heart Federation to develop national plans, at a local level within the cultural and socio-economic contexts, focused on cardiovascular health. The overarching goal is to promote and ensure the continuous and sustained improvement of cardiovascular health in the Portuguese population. The methodology identified key challenges and opportunities for the medium term, highlighted priority areas for intervention, and proposed strategic lines of action.

View Article and Find Full Text PDF

Background: Low back pain (LBP) presents with diverse manifestations, necessitating personalized treatment approaches that recognize various phenotypes within the same diagnosis, which could be achieved through precision medicine. Although prediction strategies have been explored, including those employing artificial intelligence (AI), they still lack scalability and real-time capabilities. Digital care programs (DCPs) facilitate seamless data collection through the Internet of Things and cloud storage, creating an ideal environment for developing and implementing an AI predictive tool to assist clinicians in dynamically optimizing treatment.

View Article and Find Full Text PDF

Thromboelastogram changes are associated with postoperative complications after cytoreductive surgery.

Pleura Peritoneum

September 2024

Department of Surgery B, Peritoneal Surface Malignancy and Melanoma Unit, Tel-Aviv Sourasky Medical Center, Tel Aviv, Israel.

Objectives: Cytoreductive surgery (CRS) and hyperthermic intraperitoneal chemotherapy (HIPEC) is used to treat peritoneal surface malignancies. However, surgical morbidity is high, and prediction of severe postoperative complications (SPC) is limited. We hypothesized that the changes in thromboelastogram (TEG) values following CRS could be associated with SPC.

View Article and Find Full Text PDF

Analytical modelling and analysis of the meander-line coil EMATs.

Ultrasonics

February 2025

Orisonic Technology Co., Ltd., Suzhou 100071, China. Electronic address:

The meander-line coil electromagnetic acoustic transducer (EMAT) is widely used in the field of ultrasonic nondestructive testing due to its convenience to generate specific mode of guided waves. Some design methods of the meander-coil EMATs are developed in the frequency-wavenumber domain while others in the time-space domain. In this paper, a unified theoretical framework is developed by proposing an analytical model from the system perspective.

View Article and Find Full Text PDF