Polyzwitterionic Coating of Porous Adsorbents for Therapeutic Apheresis.

J Funct Biomater

Department for Biomedical Research, Center for Biomedical Technology, University for Continuing Education Krems, 3500 Krems, Austria.

Published: November 2022

Adsorbents for whole blood apheresis need to be highly blood compatible to minimize the activation of blood cells on the biomaterial surface. Here, we developed blood-compatible matrices by surface modification with polyzwitterionic polysulfobetainic and polycarboxybetainic coatings. Photoreactive zwitterionic terpolymers were synthesized by free-radical polymerization of zwitterionic, photoreactive, and fluorescent monomers. Upon UV irradiation, the terpolymers were photodeposited and mutually crosslinked on the surface of hydrophobic polystyrene--divinylbenzene and hydrophilic polyacrylamide--polyacrylate (DALI) beads. Fluorescent microscopy revealed coatings with an average thickness of 5 µm, which were limited to the bead surface. Blood compatibility was assessed based on polymer-induced hemolysis, coagulation parameters, and in vitro tests. The maintenance of the adsorption capacity after coating was studied in human whole blood with cytokines for polystyrene beads (remained capacity 25-67%) and with low-density lipoprotein (remained capacity 80%) for polyacrylate beads. Coating enhanced the blood compatibility of hydrophobic, but not of hydrophilic adsorbents. The most prominent effect was observed on coagulation parameters (e.g., PT, aPTT, TT, and protein C) and neutrophil count. Polycarboxybetaine with a charge spacer of five carbons was the most promising polyzwitterion for the coating of adsorbents for whole blood apheresis.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9680258PMC
http://dx.doi.org/10.3390/jfb13040216DOI Listing

Publication Analysis

Top Keywords

adsorbents blood
8
blood apheresis
8
blood compatibility
8
coagulation parameters
8
remained capacity
8
blood
7
polyzwitterionic coating
4
coating porous
4
adsorbents
4
porous adsorbents
4

Similar Publications

Background: Contrast-associated acute kidney injury (CA-AKI) is frequent in patients with chronic kidney disease who are submitted to cardiac endovascular procedures using iodinated contrast. In hemoadsorption, cartridges containing styrene-divinylbenzene sorbent resin are applied to remove substances from the blood through an extracorporeal circuit. Importantly, iodinated contrast is also removed via adsorption.

View Article and Find Full Text PDF

The dialysis membrane based on a hydrophilic polymer (Hydrolink NV) was designed to enhance the movement of adsorbed water at the blood-membrane interface, aiming to achieve antithrombogenic and antifouling effects. This study aimed to assess the performance and albumin loss of the Hydrolink NV dialyzer in hemodialysis (HD) and post-dilution hemodiafiltration (HDF) with different infusion flows (Qis) and compare it with the hydrophilic FX CorAL dialyzer in post-dilution HDF. A prospective study was carried out in 20 patients.

View Article and Find Full Text PDF

Tumor hypoxia significantly limits the effectiveness of radiotherapy, as oxygen is crucial for producing cancer-killing reactive oxygen species. To address this, we synthesized nanosized faujasite (PBS-Na-FAU) zeolite crystals using clinical-grade phosphate-buffered saline (PBS) as the solvent, ensuring preserved crystallinity, microporous volume, and colloidal stability. The zeolite nanocrystals showed enhanced safety profiles and , and studies showed no apparent toxicity to animals.

View Article and Find Full Text PDF

BACKGROUND Extracorporeal blood purification strategies were recently developed as adjunctive treatments for sepsis. CytoSorb® is an approved medical device designed to reduce blood levels of inflammatory cytokines. The oXiris high-adsorption membrane filter is used in continuous hemofiltration adsorption.

View Article and Find Full Text PDF

Type B aortic dissection (TBAD) primarily affects men aged 60-65, with hypertension in over 80% of cases. The gold standard for the treatment of uncomplicated acute TBAD is Best Medical Therapy (BMT), which focused on controlling blood pressure and heart rate. However, Thoracic Endovascular Aortic Repair (TEVAR) has gained attention over the years, especially for complicated TBAD cases, by covering the primary entry tear, lowering false lumen pressure, and promoting aortic remodeling.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!