Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: This study was aimed to compare the stability of stainless steel and titanium miniscrew implants of the same diameter and length during en masse retraction of maxillary and mandibular anterior teeth.
Materials And Methods: Forty miniscrew implants (1.3 mm diameter and 8 mm length) were placed in 10 patients (20 titanium and 20 stainless steel). Stability was checked at insertion (T0), at one month (T1), and at sixth months (T2) and the amount of retraction was recorded in millimeters.
Results: Titanium and stainless steel implants were equally stable at the time of insertion. At T1, three titanium miniscrew implants showed grade 2 mobility, whereas seven stainless steel miniscrew implants showed grade 2 mobility. For T2, none of the titanium miniscrew implants had grade 2 mobility while four stainless steel miniscrew implants resulted in grade 2 mobility. Both had an equal frequency of grade 3 and grade 4 mobility. However, the difference in the stability was not statistically significant. No statistical significance was found when the amount of retraction achieved by titanium and stainless steel miniscrew implants was compared between the maxillary and mandibular arches.
Conclusion: Both titanium and stainless steel miniscrew implants provide good anchorage and remain stable during en masse retraction of maxillary and mandibular anterior teeth. Thus, both miniscrews are clinically effective.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674937 | PMC |
http://dx.doi.org/10.4103/jos.jos_198_21 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!