A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Validation of pitchAI markerless motion capture using marker-based 3D motion capture. | LitMetric

This study sought to compare and validate baseball pitching mechanics, including joint angles and spatiotemporal parameters, from a single camera markerless motion capture solution with a 3D optical marker-based system. Ten healthy pitchers threw 2-3 maximum effort fastballs while concurrently using marker-based optical capture and pitchAI (markerless) motion capture. Time-series measures were compared using -squared (r), and root mean square error (RMSE). Discrete kinematic measures at foot plant, maximal shoulder external rotation, and ball release, plus four spatiotemporal parameters were evaluated using descriptive statistics, Bland-Altman analyses, Pearson's correlation coefficients, p-values, r, and RMSE. For time-series angles, r ranged from 0.69 (glove arm shoulder external rotation) to 0.98 (trunk and pelvis rotation), and RMSE ranged from 4.37° (trunk lateral tilt) to 20.78° (glove arm shoulder external rotation). Bias for individual joint angle and spatiotemporal parameters ranged from -11.31 (glove arm shoulder horizontal abduction; MER) to 12.01 (ball visible). RMSE was 3.62 m/s for arm speed, 5.75% height for stride length and 21.75 ms for the ball visible metric. pitchAI can be recommended as a markerless alternative to marker-based motion capture for quantifying pitching kinematics. A database of pitchAI ranges should be established for comparison between systems.

Download full-text PDF

Source
http://dx.doi.org/10.1080/14763141.2022.2137425DOI Listing

Publication Analysis

Top Keywords

motion capture
20
markerless motion
12
spatiotemporal parameters
12
shoulder external
12
external rotation
12
glove arm
12
arm shoulder
12
pitchai markerless
8
marker-based motion
8
ball visible
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!