Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: Dose-escalation in rectal cancer (RCa) may result in an increased complete response rate and thereby enable omission of surgery and organ preservation. In order to implement dose-escalation, it is crucial to develop a technique that allows for accurate image-guided radiotherapy. The aim of the current study was to determine the performance of a novel liquid fiducial marker (BioXmark®) in RCa patients during the radiotherapy course by assessing its positional stability on daily cone-beam CT (CBCT), technical feasibility, visibility on different imaging modalities and safety.
Materials And Methods: Prospective, non-randomized, single-arm feasibility trial with inclusion of twenty patients referred for neoadjuvant chemoradiotherapy for locally advanced RCa. Primary study endpoint was positional stability on CBCT. Furthermore, technical aspects, safety and clinical performance of the marker, such as visibility on different imaging modalities, were evaluated.
Results: Seventy-four markers from twenty patients were available for analysis. The marker was stable in 96% of the cases. One marker showed clinically relevant migration, one marker was lost before start of treatment and one marker was lost during treatment. Marker visibility was good on computed tomography (CT) and CBCT, and moderate on electronic portal imaging (). Marker visibility on magnetic resonance imaging (MRI) was poor during response evaluation.
Conclusion: The novel liquid fiducial marker demonstrated positional stability. We provide evidence of the feasibility of the novel fiducial marker for image-guided radiotherapy on daily cone beam CT for RCa patients.