A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

3D Printing and Computer-Aided Design for Precision Osteotomy-Aided Modules in Bone Biomechanical Study. | LitMetric

Precise and shape-matching osteotomy models are determinants of the experimental homogeneity in the assessment of orthopedic biomechanical properties. At present, however, publications on detailed description of osteotomy in bone biomechanical study are scanty. The purposes of this study were to design a new method of osteotomy-aided module production for bone biomechanical study with the help of three-dimensional (3D) printing and computer-aided design (CAD) and to test the accuracy of osteotomy. Fourteen fourth-generation composite femurs were analyzed. The composite bone was scanned using computed tomography (CT) scanner and loaded in Mimics for reconstruction and, then, imported into 3-Matic software to design intertrochanteric region, distal femur, and rotation control lever models. 3D printer was used to print each component. After assembling Sawbones and osteotomy modules, a horizontal band-saw was used to create fracture models. The volume and mass of intermediate fragments were calculated and analyzed. Satisfactory osteotomies of all composite Sawbones were achieved. The mean volume and mass of intermediate fragments were 21.0 ± 1.5 mm and 19.0 ± 1.2 g, respectively. Range of deviation from average of volumes was -1.9 - 2.8 mm and most of these deviations fall within the range of -1.4 - 2.1 mm. Range of deviation from average of mass was -2.0 - 1.6 g and most of these deviations fall within the range of -1.4 - 1.6 g. One-dimensional histogram of deviation from average shows the precise and stable osteotomy performed based on the modules accordingly. A new method of osteotomy-aided module production for bone biomechanical study with the help of 3D printing and CAD was designed and the accuracy of osteotomy was verified. This method is expected to achieve homogeneity and standardization of osteotomy in bone biomechanical study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668582PMC
http://dx.doi.org/10.18063/ijb.v8i4.607DOI Listing

Publication Analysis

Top Keywords

bone biomechanical
20
biomechanical study
20
deviation average
12
printing computer-aided
8
computer-aided design
8
osteotomy bone
8
method osteotomy-aided
8
osteotomy-aided module
8
module production
8
production bone
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!