Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Precise and shape-matching osteotomy models are determinants of the experimental homogeneity in the assessment of orthopedic biomechanical properties. At present, however, publications on detailed description of osteotomy in bone biomechanical study are scanty. The purposes of this study were to design a new method of osteotomy-aided module production for bone biomechanical study with the help of three-dimensional (3D) printing and computer-aided design (CAD) and to test the accuracy of osteotomy. Fourteen fourth-generation composite femurs were analyzed. The composite bone was scanned using computed tomography (CT) scanner and loaded in Mimics for reconstruction and, then, imported into 3-Matic software to design intertrochanteric region, distal femur, and rotation control lever models. 3D printer was used to print each component. After assembling Sawbones and osteotomy modules, a horizontal band-saw was used to create fracture models. The volume and mass of intermediate fragments were calculated and analyzed. Satisfactory osteotomies of all composite Sawbones were achieved. The mean volume and mass of intermediate fragments were 21.0 ± 1.5 mm and 19.0 ± 1.2 g, respectively. Range of deviation from average of volumes was -1.9 - 2.8 mm and most of these deviations fall within the range of -1.4 - 2.1 mm. Range of deviation from average of mass was -2.0 - 1.6 g and most of these deviations fall within the range of -1.4 - 1.6 g. One-dimensional histogram of deviation from average shows the precise and stable osteotomy performed based on the modules accordingly. A new method of osteotomy-aided module production for bone biomechanical study with the help of 3D printing and CAD was designed and the accuracy of osteotomy was verified. This method is expected to achieve homogeneity and standardization of osteotomy in bone biomechanical study.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668582 | PMC |
http://dx.doi.org/10.18063/ijb.v8i4.607 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!