Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Remdesivir (REM) and Favipiravir (FAV) are recently approved antivirals prescribed in severely ill COVID-19 patients. Therefore, development of new, simple, rapid, sensitive, and selective methods for analysis of such drugs in their pharmaceutical formulations will be highly advantageous. Herein, we have developed different spectrophotometric methods for analysis of the studied analytes. Method I is based on direct spectrophotometric analysis of REM and FAV in ethanol at λ 244 and 323 nm, respectively. For simultaneous quantitation of REM and FAV, methods II-V were followed. Method II is based on derivative spectrophotometry in which REM was determined in second-order derivative spectra at 248 nm (the zero-crossing wavelength for FAV), while FAV was measured in first-order derivative spectra at 337 nm (the zero-crossing point for REM). Method III is the dual-wavelength method in which spectral intensities were subtracted at 244-207 nm for REM and at 330-400 nm for FAV. Method IV is the ratio subtraction in which ratio spectra were obtained by a suitable divisor followed by subtraction of intensities at 272-340 nm and 335-222 nm for REM and FAV, respectively. Method V is the derivative ratio method in which the obtained ratio spectra in method IV were converted to first-order derivative and then REM and FAV were recorded at 280 and 340 nm, respectively. Calibration graphs were linear in the ranges of 1-10 µg/mL for REM through all methods and 1-20 µg/mL for FAV in methods I and II, and 2-20 µg/mL by the other methods. The evolved methods were applied to pharmaceutical dosage forms of REM and FAV. All the proposed methods were further applied to human plasma samples containing both drugs with acceptable mean recoveries.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9650262 | PMC |
http://dx.doi.org/10.1016/j.saa.2022.122070 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!