Hybrid Approach Using the Cusp-Overlap Technique for Transcatheter Aortic Valve Replacement With a Balloon-Expandable Valve.

JACC Cardiovasc Interv

Centres for Heart Valve Innovation and for Cardiovascular Innovation, St. Paul's and Vancouver General Hospitals, Vancouver, British Columbia, Canada; Division of Cardiology, University of British Columbia & St. Paul's Hospital, Vancouver, British Columbia, Canada; Cardiovascular Translational Laboratory, Centre for Heart Lung Innovation, University of British Columbia & St. Paul's Hospital, Vancouver, British Columbia, Canada. Electronic address:

Published: December 2022

AI Article Synopsis

  • The cusp-overlap (CO) technique is a new method for placing heart valves in patients and is becoming more popular.
  • This study looked at how well this method works, how deep the valves are placed, and the results after one month for older patients receiving a specific heart valve called SAPIEN 3.
  • The CO technique was found to be safe and helps to place the heart valve better, but more research is needed to see if it can lower complications like needing a pacemaker.

Article Abstract

Background: The cusp-overlap (CO) technique has recently been advocated and is being increasingly adopted for self-expandable transcatheter heart valve (THV) implantation.

Objectives: The aim of this study was to evaluate the feasibility, implantation depth, and outcomes of the CO technique for the balloon-expandable SAPIEN 3 THV.

Methods: The CO technique was used in consecutive patients undergoing balloon-expandable THV implantation at one center between April 2021 and March 2022. Optimal fluoroscopic angles were determined from preprocedural computed tomography and confirmed on predeployment angiography. The THV radiolucent line was positioned 2 to 4 mm below the noncoronary cusp in the CO view, and positioning was confirmed in the 3-cusp view. Postdeployment THV implantation depth was assessed in both views. One-month outcomes were assessed using Valve Academic Research Consortium 3 criteria.

Results: Among 137 patients eligible for the CO technique, the CO view was not used because of unfavorable ergonomics in 27 patients (26.5%) and hemodynamic instability in 8 patients (7.8%). Among 102 patients, the mean age was 81.1 ± 6.6 years, the mean Society of Thoracic Surgeons score was 3.3% ± 2.2%, and 64.7% were men. The mean measured THV implantation depth was 3.0 ± 1.4 mm in the CO view and 2.5 ± 1.4 mm in the 3-cusp view. At 1-month follow-up, 1 patient (1.0%) had died, 1 (1.0%) had had a stroke, and 7 (6.8%) had undergone permanent pacemaker implantation.

Conclusions: The CO technique is feasible and safe and may facilitate more accurate balloon-expandable THV positioning, especially when deep implantation needs to be avoided. Further studies are required to explore potential reduction in atrioventricular conduction block, pacemakers, or paravalvular regurgitation.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2022.10.035DOI Listing

Publication Analysis

Top Keywords

implantation depth
12
thv implantation
12
cusp-overlap technique
8
balloon-expandable thv
8
3-cusp view
8
technique
6
thv
6
implantation
5
patients
5
view
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!