Introduction: Sliding compression fixation and length-stable fixation are two basic internal fixation concepts in the treatment of displaced femoral neck fractures. In this study, we aimed to compare the reoperation rates for different methodologies of internal fixation for femoral neck fractures in young and middle-aged population.

Materials And Methods: This a retrospective study. A total of 215 patients with displaced femoral neck fractures treated with cannulated screw fixation were enrolled and divided into the sliding compression and length-stable groups according to the fixation pattern. The occurrence of and reason for revision surgery within one year were recorded. Forty-five patients with complete CT data (including CT scanning on the first postoperative day and at the last follow up) were selected from the total sample. A newly established computerized image processing method was used to evaluate variations in the spatial location of screws.

Results: The reoperation rate was significantly higher in the length-stable group (23.8%) than in the sliding compression group (7.3%). The rate of revision surgery due to nonunion was also higher in the length-stable group (11.4%) than in the sliding compression group (1.8%). However, no significant difference was observed in terms of joint penetration or soft tissue irritation. The sliding compression group (6.58 ± 3.18 mm) showed higher femoral neck shortening than length-stable group (4.16 ± 3.65 mm). When analyzing the spatial variations, a significantly greater screw withdrawal distance was observed in the sliding compression group than in the length-stable group, but with a smaller rotation angle.

Conclusion: Length-stable internal fixation of displaced femoral neck fractures may lead to an increased reoperation rate in young and middle-aged population.

Trial Registration: Name of the registry: Chinese Clinical Trial Registry.

Trial Registration Number: ChiCTR2000032327. Trial registration date: 2020-4-26.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9673360PMC
http://dx.doi.org/10.1186/s12891-022-05956-9DOI Listing

Publication Analysis

Top Keywords

sliding compression
28
femoral neck
24
neck fractures
20
displaced femoral
16
length-stable group
16
compression group
16
reoperation rate
12
young middle-aged
12
internal fixation
12
length-stable
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!