Results of the Interlaboratory Computational Fluid Dynamics Study of the FDA Benchmark Blood Pump.

Ann Biomed Eng

Division of Applied Mechanics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, MD, USA.

Published: January 2023

Computational fluid dynamics (CFD) is widely used to simulate blood-contacting medical devices. To be relied upon to inform high-risk decision making, however, model credibility should be demonstrated through validation. To provide robust data sets for validation, researchers at the FDA and collaborators developed two benchmark medical device flow models: a nozzle and a centrifugal blood pump. Experimental measurements of the flow fields and hemolysis were acquired using each model. Concurrently, separate open interlaboratory CFD studies were performed in which participants from around the world, who were blinded to the measurements, submitted CFD predictions of each benchmark model. In this study, we report the results of the interlaboratory CFD study of the FDA benchmark blood pump. We analyze the results of 24 CFD submissions using a wide range of different flow solvers, methods, and modeling parameters. To assess the accuracy of the CFD predictions, we compare the results with experimental measurements of three quantities of interest (pressure head, velocity field, and hemolysis) at different pump operating conditions. We also investigate the influence of different CFD methods and modeling choices used by the participants. Our analyses reveal that, while a number of CFD submissions accurately predicted the pump performance for individual cases, no single participant was able to accurately predict all quantities of interest across all conditions. Several participants accurately predicted the pressure head at all conditions and the velocity field in all but one or two cases. Only one of the eight participants who submitted hemolysis results accurately predicted absolute plasma free hemoglobin levels at a majority of the conditions, though most participants were successful at predicting relative hemolysis levels between conditions. Overall, this study highlights the need to validate CFD modeling of rotary blood pumps across the entire range of operating conditions and for all quantities of interest, as some operating conditions and regions (e.g., the pump diffuser) are more challenging to accurately predict than others. All quantities of interest should be validated because, as shown here, it is possible to accurately predict hemolysis despite having relatively inaccurate predictions of the flow field.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-022-03105-wDOI Listing

Publication Analysis

Top Keywords

quantities interest
16
blood pump
12
operating conditions
12
accurately predicted
12
accurately predict
12
cfd
9
computational fluid
8
fluid dynamics
8
study fda
8
fda benchmark
8

Similar Publications

Purpose Of Review: The purpose of this review is to outline considerations for treating older adults with rheumatoid arthritis-associated interstitial lung disease (RA-ILD) as it relates to infection, comorbidities, cancer, and quality of life.

Recent Findings: The recent 2023 American College of Rheumatology/American College of Chest Physicians guideline conditionally recommended specific disease-modifying antirheumatic drugs (DMARDs), antifibrotics, and short-term glucocorticoids to treat RA-ILD. Since RA-ILD often affects older adults, we contextualize these pharmacologic options related to infection, gastrointestinal (GI) effects, cancer, cardiovascular disease, and quality of life.

View Article and Find Full Text PDF

The ball-pitching plugging-selection profile control technology represents an effective and low-cost means of adjusting the profile of waterflooding well. The technology primarily utilizes polymer balls to plug the perforations, thereby achieving the effect of fine profile control. This paper aims to elucidate the migration and plugging laws of plugging-selection balls in wellbore and perforation plugging processes.

View Article and Find Full Text PDF

A label-free electrochemical biosensor based on graphene quantum dots-nanoporous gold nanocomposite for highly sensitive detection of glioma cell.

Anal Chim Acta

February 2025

School of Life Sciences, The Second Affiliated Hospital, Medical Science and Technology Innovation Center, Shandong First Medical University & Shandong Academy of Medical Sciences, Jinan, 250117, PR China. Electronic address:

Background: Glioma accounts for 80 % of all malignant primary brain tumors with a high mortality rate. Histopathological examination is the current diagnostic methods for glioma, but its invasive surgical interventions can cause cerebral edema or impair neural functioning. Liquid biopsy proves to be an efficient method for glioma detection.

View Article and Find Full Text PDF

KNG1 mutations (c.618 T > G and c.1165C > T) cause disruption of the Cys206-Cys218 disulfide bond and truncation of the D5 domain leading to hereditary high molecular weight kininogen deficiency.

Clin Biochem

January 2025

Key Laboratory of Clinical Laboratory Medicine of Guangxi Department of Education, Nanning, Guangxi, China; Department of Clinical Laboratory, The First Affiliated Hospital of Guangxi Medical University, Nanning, Guangxi, China; Key Laboratory of Hematology, Guangxi Medical University, Education Department of Guangxi Zhuang Autonomous Region, Nanning, Guangxi, China. Electronic address:

Background: High molecular weight kininogen (HMWK), encoded by the kininogen-1 (KNG1) gene, is a multifunctional glycoprotein closely associated with the initiation of blood coagulation, tumor growth, and other pathological processes.

Objective: We conducted a study on the clinical phenotype, genetic mutations, and molecular pathogenesis of a female patient with uterine leiomyosarcoma, who presented with HMWK deficiency and an isolated prolonged activated partial thromboplastin time (APTT).

Methods: Clinical phenotyping was conducted through APTT mixing studies, quantitative assessments of intrinsic coagulation factor activities, antigen levels of HMWK, and thromboelastography.

View Article and Find Full Text PDF

Innovative submerged directed fermentation: Producing high molecular weight polysaccharides from Ganoderma lucidum.

Food Chem

January 2025

Key Laboratory of Edible Fungi Resources and Utilization (South) of Ministry of Agriculture, China. National Engineering Research Center of Edible Fungi, Key Laboratory of Agricultural Genetics and Breeding of Shanghai, Institute of Edible Fungi, Shanghai Academy of Agricultural Sciences, 1000 Jinqi Road, Fengxian District, Shanghai 201403, China. Electronic address:

Polysaccharides from Ganoderma lucidum (GLPs) exhibit unique bioactivity, but traditional cultivation yields low quantities and unstable quality, limiting their research and application. This study highlights how submerged fermentation processes enable the directed acquisition of structurally defined high molecular weight (MW) bioactive intracellular polysaccharides (IPS). The results showed that inoculation amount and fermentation scales had a significant effect on the content of high MW IPS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!