Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: To verify the diagnostic utility of recombinant fusion protein ESAT6-CPF10 (EC), a novel skin test reagent to detect Mycobacterium tuberculosis infection.
Methods: A multi-centered, double-blind, randomized controlled trial was conducted from December 17, 2015, to March 2, 2018. Participants involved in this study included those with active tuberculosis (TB), suspected pulmonary TB, or non-TB pulmonary disease. Each participant received three tests simultaneously, TB-specific enzyme-linked immunospot assay (T-SPOT.TB), tuberculin skin test (TST), and EC skin test (ECST), and adverse events were reported.
Results: Diagnostic accuracy was analyzed using data from 1085 protocol-compliant participants. The sensitivities of the ECST, TST, and T-SPOT.TB were 91.2% (95% CI, 89.0-93.2%), 91.4% (95% CI, 89.1-93.3%), and 92.1% (95% CI, 89.9-93.9%), respectively. The specificities of the ECST (69.7%, 95% CI, 64.5-74.5%) and T-SPOT.TB (76.1%, 95% CI, 71.2-80.5%) were significantly higher than the TST (54.4%, 95% CI, 48.9-59.7%). The agreements between ECST and TST (kappa = 0.632) and between ECST and T-SPOT.TB (kappa = 0.780) were substantial. No severe adverse event was reported.
Conclusion: The diagnostic performance of the ECST was close to the T-SPOT.TB assay in the detection of TB infection and indicated good potential for clinical application in common scenarios.