In order to achieve better performance, artificial intelligence is used in breast cancer diagnosis. In this study, we evaluated the efficacy of different fine-tuning strategies of deep transfer learning (DTL) based on the DenseNet201 model to differentiate malignant from benign lesions on breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). We collected 4260 images of benign lesions and 4140 images of malignant lesions of the breast pertaining to pathologically confirmed cases. The benign and malignant groups was randomly divided into a training set and a testing set at a ratio of 9:1. A DTL model based on the DenseNet201 model was established, and the effectiveness of 4 fine-tuning strategies (S0: strategy 0, S1: strategy; S2: strategy; and S3: strategy) was compared. Additionally, DCE-MRI images of 48 breast lesions were selected to verify the robustness of the model. Ten images were obtained for each lesion. The classification was considered correct if more than 5 images were correctly classified. The metrics for model performance evaluation included accuracy (Ac) in the training and testing sets, precision (Pr), recall rate (Rc), f1 score (f1), and area under the receiver operating characteristic curve (AUROC) in the validation set. The Ac of the 4 fine-tuning strategies reached 100.00% in the training set. The S2 strategy exhibited good convergence in the testing set. The Ac of S2 was 98.01% in the testing set, which was higher than those of S0 (93.10%), S1 (90.45%), and S3 (93.90%). The average classification Pr, Rc, f1, and AUROC of S2 in the validation set were (89.00%, 80.00%, 0.81, and 0.79, respectively) higher than those of S0 (76.00%, 67.00%, 0.69, and 0.65, respectively), S1 (60.00%, 60.00%, 0.60, 0.66, and respectively), and S3 (77.00%, 73.00%, 0.74, 0.72, respectively). The degree of coincidence between S2 and the histopathological method for differentiating between benign and malignant breast lesions was high (κ = 0.749). The S2 strategy can improve the robustness of the DenseNet201 model in relatively small breast DCE-MRI datasets, and this is a reliable method to increase the Ac of discriminating benign from malignant breast lesions on DCE-MRI.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9666147PMC
http://dx.doi.org/10.1097/MD.0000000000031214DOI Listing

Publication Analysis

Top Keywords

breast lesions
16
based densenet201
12
fine-tuning strategies
12
densenet201 model
12
benign malignant
12
testing set
12
strategy strategy
12
dynamic contrast-enhanced
8
contrast-enhanced magnetic
8
magnetic resonance
8

Similar Publications

Purpose: This study explored the use of computer-aided diagnosis (CAD) systems to enhance mammography image quality and identify potentially suspicious areas, because mammography is the primary method for breast cancer screening. The primary aim was to find the best combination of preprocessing algorithms to enable more precise classification and interpretation of mammography images because the selected preprocessing algorithms significantly impact the effectiveness of later classification and segmentation processes.

Material And Methods: The study utilised the mini-MIAS database of mammography images and examined the impact of applying various preprocessing method combinations to differentiate between malignant and benign breast lesions.

View Article and Find Full Text PDF

Opsoclonus-myoclonus syndrome (OMS) is a rare neurological inflammatory disease of paraneoplastic, parainfectious or idiopathic origin. It is manifested by the occurrence of opsoclonus, myoclonus, ataxia, as well as behavioral and sleep disorders. The incidence is estimated at 1/5,000,000 people.

View Article and Find Full Text PDF

Neoadjuvant chemotherapy (NAC) is a systemic and systematic chemotherapy regimen for breast cancer patients before surgery. However, NAC is not effective for everyone, and the process is excruciating. Therefore, accurate early prediction of the efficacy of NAC is essential for the clinical diagnosis and treatment of patients.

View Article and Find Full Text PDF

Purpose: To evaluate the effects of four-dimensional noise reduction filtering using a similarity algorithm (4D-SF) on the image quality and tumor visibility of low-dose dynamic computed tomography (CT) in evaluating breast cancer.

Materials And Methods: Thirty-four patients with 38 lesions who underwent low-dose dynamic breast CT and were pathologically diagnosed with breast cancer were enrolled. Dynamic CT images were reconstructed using iterative reconstruction alone or in combination with 4D-SF.

View Article and Find Full Text PDF

Intrapatient heterogeneity of estrogen receptor (ER) expression on 16α-[F]fluoro-17β-estradiol ([F]FES) PET is related to outcome in patients with ER-positive metastatic breast cancer (MBC), but a validated and practical method to support clinical decision-making is lacking. Therefore, the [F]FES PET heterogeneity score (i.e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!