A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The effect of different energy levels of the Er: YAG laser on the repair bond strength of a nanohybrid composite resin. | LitMetric

The effect of different energy levels of the Er: YAG laser on the repair bond strength of a nanohybrid composite resin.

Proc Inst Mech Eng H

Department of Restorative Dentistry, Ege University, Faculty of Dentistry, Izmir, Turkey.

Published: January 2023

This study evaluates the durability of repair microshear bond strength (µSBS) of nanohybrid composite resins which surfaces are treated with different laser parameters and bur. A total of 240 nanohybrid composite resin disk shaped specimens were prepared. Then, specimens were divided into eight test groups as regards to surface treatment types (Erbium (Er:YAG) laser with seven different parameters and bur). Half of the specimens in each group were subjected to 5000 thermal cycling (TC) and the other half to 20,000 TC. Universal testing machine was used for µSBS test. The data were analyzed with a two-way analysis of variance and Tukey test. Among the specimens treated with ER:YAG laser+5000 TC, we detected the highest mean µSBS test values in the subgroups L200 and L250. Among the specimens treated with ER:YAG laser+20,000 TC, the highest mean µSBS test values were seen in the L200 subgroup. The µSBS values after the 20,000 TC were significantly lower than those after 5000 TC for all different treatment types. Thermal cycling and laser energy levels have effects on repair µSBS. Considering the bond strength and durability it seems more effective to use Er:YAG laser at 200 mJ. To repair an aged nanohybrid composite resin, Er:YAG laser surface treatments may provide some benefits by acquiring a reliable bond strength with durability. This study may give information on which parameters are more suitable to use Er:YAG laser for the repair of nanohybrid composite resins.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09544119221136253DOI Listing

Publication Analysis

Top Keywords

nanohybrid composite
20
bond strength
16
eryag laser
16
composite resin
12
µsbs test
12
energy levels
8
laser repair
8
composite resins
8
laser parameters
8
parameters bur
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!