Case report: Transcatheter edge-to-edge repair after prior surgical tricuspid annuloplasty.

Front Cardiovasc Med

Division of Cardiology, Pulmonology and Vascular Medicine, Medical Faculty, University Düsseldorf, Dūsseldorf, Germany.

Published: October 2022

Residual and recurrent tricuspid regurgitation may occur frequently after surgical tricuspid valve repair. However, reoperation for tricuspid regurgitation is rare, although many patients are again highly symptomatic. Tricuspid transcatheter edge-to-edge repair (TEER) is a promising therapy for severe tricuspid regurgitation. Herein, we report a 77-year-old woman with recurrent symptomatic massive tricuspid regurgitation 2 years after sutured annuloplasty of the tricuspid valve. TEER was successfully performed using the TriClip device and tricuspid regurgitation was reduced to a mild degree. In conclusion, tricuspid TEER is feasible following surgical suture annuloplasty. TEER is an alternative option for patients with a failed previous annuloplasty repair for tricuspid regurgitation to undergo a less invasive treatment rather than a potentially higher-risk reoperation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9650543PMC
http://dx.doi.org/10.3389/fcvm.2022.1044410DOI Listing

Publication Analysis

Top Keywords

tricuspid regurgitation
24
tricuspid
11
transcatheter edge-to-edge
8
edge-to-edge repair
8
surgical tricuspid
8
tricuspid valve
8
regurgitation
6
case report
4
report transcatheter
4
repair
4

Similar Publications

Background: Previous studies on the prevalence and prognosis of nutritional status in valvular heart disease (VHD) were primarily limited to aortic stenosis. The nutritional status of other types of VHDs remained an underexplored area.

Objectives: This study aimed to evaluate the prevalence of malnutrition risk in different types of VHD and investigate the association between malnutrition risk and adverse clinical events.

View Article and Find Full Text PDF

Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.

Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.

View Article and Find Full Text PDF

Prognostic value of left atrial stiffness in patients undergoing transcatheter aortic valve implantation.

Int J Cardiol Heart Vasc

February 2025

Department of Cardiovascular Medicine, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.

Aim: This study was performed to evaluate the association between left atrial (LA) stiffness and outcomes in patients undergoing transcatheter aortic valve implantation (TAVI).

Methods And Results: This study involved 279 patients with aortic stenosis (AS) who underwent TAVI at Kumamoto University Hospital between 2015 and 2023. During a median follow-up of 468 days (interquartile range: 258-825 days), 42 deaths occurred.

View Article and Find Full Text PDF

Transcatheter edge-to-edge repair of severe atrioventricular valve regurgitation in unrepaired functionally univentricular heart with dextroversion.

J Invasive Cardiol

January 2025

Cardiology Division, Department of Medicine, Li Ka Shing Faculty of Medicine, The University of Hong Kong, Hong Kong SAR, China; Cardiology Division, Department of Medicine, Queen Mary Hospital, Hong Kong SAR, China; Cardiac Medical Unit, Grantham Hospital, Hong Kong SAR, China.

View Article and Find Full Text PDF