A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A diagnostic accuracy study on an innovative auto-edge detection technique for identifying simulated implant fractures on radiographic images. | LitMetric

Implant fracture is a rare but devastating complication of treatment in partially or fully edentulous patients which requires prompt diagnosis. Nevertheless, studies on defining the most accurate technique for the detection of implant fractures are lacking. In the present study, the Canny edge detection algorithm was applied on multiple radiographic modalities including parallel periapical (PPA), oblique periapical (OPA), and cone beam CT (CBCT) with and without metal artifact reduction (MAR) to examine its accuracy for diagnosis of simulated implant fractures. Radiographs were taken from 24 intact implants and 24 implants with artificially created fractures. Images were evaluated in their original and Canny formats. The accuracy of each radiograph was assessed by comparison with a reference standard of direct observation of the implant. The greatest area under the receiver operating characteristic curve belonged to Canny CBCT with MAR (0.958), followed by original CBCT with MAR (0.917), original CBCT without MAR = Canny CBCT without MAR = Canny OPA (0.875), Canny PPA (0.833), original PPA = original OPA (0.792), respectively. The Canny edge detection algorithm is suggested as an innovative method for accurate diagnosis of clinically suspected implant fractures on CBCT and periapical radiographies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9668839PMC
http://dx.doi.org/10.1038/s41598-022-24266-7DOI Listing

Publication Analysis

Top Keywords

implant fractures
16
simulated implant
8
canny edge
8
edge detection
8
detection algorithm
8
cbct mar
8
original cbct
8
cbct mar = canny
8
implant
6
cbct
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!