Laser Doppler flow for the hemodynamic differentiation of tachycardia.

Pacing Clin Electrophysiol

National Heart and Lung Institute, Imperial College London, Hammersmith Hospital, United Kingdom.

Published: February 2023

AI Article Synopsis

  • Implantable cardioverter defibrillators (ICDs) help prevent sudden heart problems, but sometimes they can give shocks at the wrong times, which is not good for people.
  • This study looked at using a special device called laser Doppler flowmetry to check how the heart is doing during fast heart rates caused by atrial and ventricular issues.
  • The results showed that laser Doppler flowmetry worked well to measure blood flow and was better at spotting heart problems than just looking at the heart rate alone.

Article Abstract

Background: Implantable cardioverter defibrillators (ICDs) offer effective therapy for the prevention of sudden cardiac death (SCD) due to ventricular arrhythmias. However, inappropriate shocks have detrimental effects on survival and quality of life. The addition of hemodynamic monitoring may be useful in discriminating clinically important ventricular arrhythmias.

Objective: In this study, we assess the ability of laser Doppler flowmetry to assess the hemodynamic effect of paced atrial and ventricular arrhythmias using mean arterial blood pressure as the reference.

Methods: In this acute human study in patients undergoing an elective electrophysiological study, laser Doppler flowmetry, arterial blood pressure, and surface ECG were acquired during high-rate atrial and ventricular pacing to simulate supraventricular and ventricular tachycardias.

Results: Arterial blood pressure and laser Doppler flow signals correlated well during atrial and ventricular pacing (rho = 0.694, p < .001). The hemodynamic impairment detected by both methods was greater during ventricular pacing than atrial pacing (-1.0% vs. 19.0%, p < .001). Laser Doppler flowmetry performed better than rate alone to identify hemodynamic impairments.

Conclusion: In this acute study, laser Doppler flowmetry tissue perfusion served as a good surrogate measure for arterial pressure, which could be incorporated into future ICDs.

Download full-text PDF

Source
http://dx.doi.org/10.1111/pace.14618DOI Listing

Publication Analysis

Top Keywords

laser doppler
16
atrial ventricular
12
arterial blood
12
blood pressure
12
doppler flow
8
ventricular arrhythmias
8
doppler flowmetry
8
ventricular pacing
8
ventricular
6
laser
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!