Objective: This study aims to investigate the clinical application and feasibility of C2 subfacetal screws in patients with Klippel-Feil syndrome (KFS), narrow C2 pedicles, and high-riding vertebral arteries (HRVAs).

Methods: The clinical data of seven patients with KFS, atlantoaxial dislocation, narrow C2 pedicles, and HRVAs treated with C2 subfacetal screws were analyzed in this retrospective study. The internal height, isthmus height, and pedicle width of C2 vertebra were measured using preoperative computed tomography (CT). Subfacetal screws were inserted for 7 patients (12 sides). The position and length of the screws were observed using postoperative CT. Intraoperative dura mater and vertebral artery (VA) injuries were recorded. Bone fusion was observed using follow-up CT.

Results: The internal height was 10.5 ± 3.2 mm, the isthmus height was 3.7 ± 1.8 mm, the pedicle width was 3.0 ± 1.4 mm, and the screw length was 19.7 ± 1.5 mm. All patients had HRVAs and narrow pedicles. No injury to the dura mater and vertebral artery (VA) occurred in this group of patients. Bone fusion was achieved in all patients during follow-up.

Conclusions: In patients with KFS, HRVA, and a narrow C2 pedicle, there is sufficient space below the C2 articular surface for screw insertion. When the pedicle is narrow and the C2 pedicle screw is not suitable for placement due to possible injury to the VA, subfacetal screws are a feasible alternative.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9670565PMC
http://dx.doi.org/10.1186/s13018-022-03391-zDOI Listing

Publication Analysis

Top Keywords

subfacetal screws
20
narrow pedicle
12
vertebral artery
12
narrow pedicles
12
atlantoaxial dislocation
8
patients
8
patients klippel-feil
8
klippel-feil syndrome
8
high-riding vertebral
8
patients kfs
8

Similar Publications

Background Context: Our recent studies indicated that a high-riding vertebral artery (HRVA) is a common variant posing a risk of injuring the vessel during C2 instrumentation. However, several different types fit in the current definition of HRVA, which may require a different strategy for C2 screw placement.

Purpose: To classify HRVA and provide a clinical aid for preoperative planning of C2 instrumentation.

View Article and Find Full Text PDF

Objective: To propose a screw algorithm and investigate the anatomical feasibilities and clinical outcomes of five distinct fixation methods for C2-3 fused vertebra with high-ridding vertebral arteries (VA) (HRVA) when the C2 pedicle screw placement is unfeasible.

Methods: Thirty surgical patients with congenital C2-3 fusion, HRVA, and atlantoaxial dislocation (AAD) were included. We designed a algorithm for alternative screw implantation into C2-3 fused vertebrae, including C2 pedicle screw with in-out-in (passing VA groove) technique (in-out-in screw), subfacetal screw, translaminar screw, lateral mass screw, C3 pedicle screw.

View Article and Find Full Text PDF

Atlantoaxial instability (AAI) is surgically a complex entity due to its proximity to vital neurovascular structures. C1-C2 fusion has been an established standard in its treatment for a considerable time now. Here, we have outlined the most common techniques for C2 screw fixation in practice at present such as C2 pedicle, C2 pars, C2 translaminar, C2 subfacetal, C2-C3 transfacetal, and C2 inferior facet screw.

View Article and Find Full Text PDF

Objective: This study aims to investigate the clinical application and feasibility of C2 subfacetal screws in patients with Klippel-Feil syndrome (KFS), narrow C2 pedicles, and high-riding vertebral arteries (HRVAs).

Methods: The clinical data of seven patients with KFS, atlantoaxial dislocation, narrow C2 pedicles, and HRVAs treated with C2 subfacetal screws were analyzed in this retrospective study. The internal height, isthmus height, and pedicle width of C2 vertebra were measured using preoperative computed tomography (CT).

View Article and Find Full Text PDF

A C2 pedicle screw provides robust construct for fixation in atlantoaxial dislocation. However, inserting a C2 pedicle screw with the standard technique in cases with narrow pedicle and high-riding vertebral artery (VA) may endanger the artery. A pars screw is also risky and biomechanically inferior.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!