A simple and practical solvent system selection strategy for high-speed countercurrent chromatography based on the HPLC polarity parameter model.

Anal Methods

Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Department of Engineering Physics, Tsinghua University, Beijing 100084, P. R. China.

Published: December 2022

The selection of an appropriate solvent system is the most crucial step in high-speed countercurrent chromatography (HSCCC) separation. The compound polarity plays an important role in HPLC analysis and HSCCC separation, and it can be calculated by the HPLC polarity parameter model and the average polarity of the HSCCC solvent system, respectively. However, flow rates, columns and methanol concentrations of the HPLC experiment can influence the calculation of the compound polarity. Therefore, the applicability and accuracy of the HPLC polarity parameter model still needed to be extensively validated. We chose 14 compounds to conduct the shake-flask experiments and HPLC analysis on, such as apigenin, honokiol, phloridzin and dihydromyricetin. The HPLC analysis results showed that different flow rates and columns have negligible effects on the calculated compound polarities. However, there was a certain variation trend in the calculated polarities with different methanol concentrations. Although the polarity values of some compounds showed a difference between the HPLC analysis and shake-flask experiments, their partition coefficients () in the HSCCC solvent systems were still located in the range of 0.5 < < 2.0. Guided by the HPLC polarity parameter model, the appropriate HSCCC solvent systems for mangosteen peel and Hance were selected, and the two main components (mangostin and quercetin) were isolated from their extracts, respectively. The separation results showed that the predicted compound polarities were sufficient to meet the HSCCC separation requirements. Meanwhile, this method required only 1 to 2 HPLC analyses with reference compounds, greatly improved the efficiency of the HSCCC solvent system selection, and shortened the experimental time. The polarity parameter model was a fast and efficient analysis method for the selection of an appropriate HSCCC solvent system.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d2ay01377kDOI Listing

Publication Analysis

Top Keywords

solvent system
20
polarity parameter
20
parameter model
20
hsccc solvent
20
hplc polarity
16
hplc analysis
16
hsccc separation
12
hplc
10
polarity
9
system selection
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!