Targeted Deformable Motion Compensation for Vascular Interventional Cone-Beam CT Imaging.

Proc SPIE Int Soc Opt Eng

Russell H. Morgan Department of Radiology, Johns Hopkins University, Baltimore, MD USA.

Published: April 2022

Purpose: Cone-beam CT has become commonplace for 3D guidance in interventional radiology (IR), especially for vascular procedures in which identification of small vascular structures is crucial. However, its long image acquisition time poses a limit to image quality due to soft-tissue deformable motion that hampers visibility of small vessels. Autofocus motion compensation has shown promising potential for soft-tissue deformable motion compensation, but it lacks specific target to the imaging task. This work presents an approach for deformable motion compensation targeted at imaging of vascular structures.

Methods: The proposed method consists on a two-stage framework for: i) identification of contrast-enhanced blood vessels in 2D projection data and delineation of an approximate region covering the vascular target in the volume space, and, ii) a novel autofocus approach including a metric designed to promote the presence of vascular structures acting solely in the region of interest. The vesselness of the image is quantified via evaluation of the properties of the 3D image Hessian, yielding a vesselness filter that gives larger values to voxels candidate to be part of a tubular structure. A cost metric is designed to promote large vesselness values and spatial sparsity, as expected in regions of fine vascularity. A targeted autofocus method was designed by combining the presented metric with a conventional autofocus term acting outside of the region of interest. The resulting method was evaluated on simulated data including synthetic vascularity merged with real anatomical features obtained from MDCT data. Further evaluation was obtained in two clinical datasets obtained during TACE procedures with a robotic C-arm (Artis Zeego, Siemens Healthineers).

Results: The targeted vascular autofocus effectively restored the shape and contrast of the contrast-enhanced vascularity in the simulation cases, resulting in improved visibility and reduced artifacts. Segmentations performed with a single threshold value on the target vascular regions yielded a net increase of up to 42% in DICE coefficient computed against the static reference. Motion compensation in clinical datasets resulted in improved visibility of vascular structures, observed in maximum intensity projections of the contrast-enhanced liver vessel tree.

Conclusion: Targeted motion compensation for vascular imaging showed promising performance for increased identification of small vascular structures in presence of motion. The development of autofocus metrics and methods tailored to vascular imaging opens the way for reliable compensation of deformable motion while preserving the integrity of anatomical structures in the image.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9654751PMC
http://dx.doi.org/10.1117/12.2613232DOI Listing

Publication Analysis

Top Keywords

motion compensation
24
deformable motion
20
vascular structures
16
vascular
12
motion
9
compensation vascular
8
identification small
8
small vascular
8
soft-tissue deformable
8
metric designed
8

Similar Publications

Measuring the effects of motion corruption in fetal fMRI.

Hum Brain Mapp

February 2025

Computational Imaging Research Lab, Department of Biomedical Imaging and Image-Guided Therapy, Medical University of Vienna, Vienna, Austria.

Irregular and unpredictable fetal movement is the most common cause of artifacts in in utero functional magnetic resonance imaging (fMRI), affecting analysis and limiting our understanding of early functional brain development. The accurate detection of corrupted functional connectivity (FC) resulting from motion artifacts or preprocessing, instead of neural activity, is a prerequisite for reliable and valid analysis of FC and early brain development. Approaches to address this problem in adult data are of limited utility in fetal fMRI.

View Article and Find Full Text PDF

Sprengel deformity: What is the functional outcome of conservative treatment versus surgical correction?

Orphanet J Rare Dis

January 2025

Paediatric Orthopaedics, Deformity Reconstruction and Foot Surgery, General Orthopaedics and Tumour Orthopaedics, Muenster University Hospital, Albert-Schweitzer-Campus 1, Muenster, 48149, Germany.

Background: Sprengel deformity is a rare congenital malformation of the scapula defined by malposition during embryonic development. Affected individuals have limited range of motion of the shoulder and torticollis. Surgical reconstruction is an option to treat patients with severe deformity and functional impairment.

View Article and Find Full Text PDF

Purpose: Redox homeostasis plays a key role in regulating the overall health and development of organisms. This study aimed to develop a compact and mobile continuous-wave (CW) electron paramagnetic resonance (EPR) imager to facilitate stable, highly sensitive fast three-dimensional (3D) whole-body imaging of nitroxide-infused mice.

Methods: A multiturn loop gap resonator with a diameter of 30 mm and length of 35 mm was designed for whole-body EPR imaging.

View Article and Find Full Text PDF

PTV Margins in MR-guided and Beam-gated SBRT of Liver Metastases: GTV Dose Escalation Can Reduce the Required PTV.

Clin Oncol (R Coll Radiol)

December 2024

Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark; Department of Oncology, Copenhagen University Hospital - Herlev and Gentofte, Herlev, Denmark.

Aims: Determining appropriate PTV margins for SBRT of liver metastases is a non-trivial task, especially with motion management included. The widely used analytical van Herk margin recipe (van Herk et al., 2000) could break down due to (i) a low number of fractions, (ii) non-Gaussian errors, or (iii) non-homogenous dose distributions.

View Article and Find Full Text PDF

A characteristic feature of redundancy in the motor system is the ability to compensate for the failure of individual motor elements without affecting task performance. In this study, we examined the pattern and variability in error compensation between motor elements during a virtual task. Participants performed a redundant cursor control task with finger movements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!