Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Poly(styrene) (PS) 96-well plates were surface modified to improve the detection performances of an otherwise traditional enzyme-linked immunosorbent assay (ELISA). Poly(amidoamine) generation 7 (G7) dendrimers were covalently immobilized on the surface of PS plates and subsequently conjugated with aptamers specific for a model analyte, i.e., human platelet-derived growth factor BB (PDGF-BB). This surface functionalization was followed by Fourier-transform infrared spectroscopy, water contact angle, atomic force microscopy, and X-ray photoelectron spectroscopy (XPS) to confirm the success of the modifications. Moreover, the assay performances of the G7-aptamer modified PS plates were compared to those of traditional ELISA performed on regular PS 96-well plates. The G7-aptamer assay demonstrated a 2.3-time broader linear detection range and a 13-time improved detection limit than the traditional ELISA. More importantly, the new G7-aptamer modified PS plates also showed excellent analytical specificities, detection recoveries, and precisions when the targets were assayed in a cell culture medium. This combined dendrimer templates and aptamers surface modification approach significantly reduces background noises and increases detection signals, and can be readily incorporated into existing ELISA workflows and many other PS microplate based high throughput and automated bioassays.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.colsurfb.2022.113003 | DOI Listing |