Sternal-sparing aortic valve replacement with sutureless valve in bicuspid valve.

J Card Surg

Department of Cardiothoracic Surgery, Lankenau Heart Institute, Lankenau Medical Center, Main Line Health, Wynnewood, Pennsylvania, USA.

Published: December 2022

Over the last decade, sutureless valves (Perceval, LivaNova PLC) were brought to the market as an alternative to stented valves for patients requiring surgical aortic valve replacement (SAVR). However, Perceval demands special steps for implantation, among which we can mention specific training for the surgical team members. Sternal-sparing cardiac procedures are conceived to limit surgical trauma, but the technical requirements and preoperative planning are more challenging than those for conventional sternotomy. SAVR is frequently carried out through an upper hemisternotomy, but the right anterior thoracotomy (RAT) represents an even less traumatic, technical advancement. In the context of SAVR with RAT, Perceval has been considered the "perfect marriage." In patients with bicuspid aortic valve (BAV), some surgeons initially avoided the Perceval valve but, with growing experience, the prosthesis has been used for a wide variety of indications. According to an international consensus statement recently published, there are 3 BAV types: the fused BAV, the 2-sinus BAV and the partial-fusion BAV, each with specific phenotypes. The 2-sinus BAV has 2 cusps, roughly equal in size and shape, each cusp occupying 180° of the annular circumference, with only 2 aortic sinuses, resulting in a 2-sinus/2-cusp valve without raphe and with 180° commissural angles. Since the elliptic aortic annulus in BAV patients poses a challenge for sutureless valves and the RAT approach has been increasingly adopted for minimally invasive SAVR, our description of the surgical technique focuses on the specific procedural details in the scenario of 2-sinus BAV laterolateral phenotype.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jocs.17185DOI Listing

Publication Analysis

Top Keywords

aortic valve
12
2-sinus bav
12
valve replacement
8
sutureless valves
8
bav
8
valve
7
sternal-sparing aortic
4
replacement sutureless
4
sutureless valve
4
valve bicuspid
4

Similar Publications

: New-onset postoperative atrial fibrillation (POAF) is the most common complication after cardiac surgery, occurring approximately in one-third of the patients. This study considered all-comer patients who underwent cardiac surgery to build a predictive model for POAF. : A total of 3467 (Center 1) consecutive patients were used as a derivation cohort to build the model.

View Article and Find Full Text PDF

Paravalvular leak (PVL) was initially recognized as one of the most common complications after transcatheter aortic valve implantation (TAVI) and has been linked to adverse clinical outcomes, including mortality. This study aims to assess the long-term clinical effects of PVL in patients undergoing TAVI with the latest generation of transcatheter aortic valves, as part of the national observational prospective multicenter study OBSERVANT II. OBSERVANT II included all consecutive patients with severe aortic stenosis who underwent TAVI across 28 Italian centers from December 2016 to September 2018.

View Article and Find Full Text PDF

Previous studies evaluated the prognostic role of hematological parameters in predicting outcome in patients with infective endocarditis (IE). However, only a few studies evaluated the role of hematological parameters in patients undergoing surgery for IE. The aim of this study was to review our 20-year experience with the treatment of native (NVE) and prosthetic (PVE) valve endocarditis and to evaluate the role of neutrophil-to-lymphocyte ratio (NLR), neutrophil-to-platelet ratio (NPR), platelet-to-lymphocyte ratio (PLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-to monocyte ratio (NMR), and systemic inflammatory index (SII) on early and long-term outcomes of patients undergoing surgery for NVE and PVE.

View Article and Find Full Text PDF

Stuck prosthetic valves, often resulting from pannus formation or thrombus accumulation, represent a critical complication in prosthetic valve management, carrying significant risks for morbidity and mortality. This study aims to identify factors associated with stuck valve development and assess the effectiveness of interventions in restoring normal valve function. A total of 27 patients with stuck valves were analyzed, including mitral, aortic, and tricuspid valve cases.

View Article and Find Full Text PDF

Myocardial work (MW) is a new echocardiographic parameter used in the assessment of cardiac energy expenditure. The aim of the current study was to evaluate changes in left ventricular MW parameters in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI). One hundred and thirty five consecutive patients who underwent TAVI at one center were evaluated before and after the procedure using transthoracic echocardiography (TTE) to assess the following MW indices: global constructive work (GCW), global wasted work (GWW), global work index (GWI) and global work efficiency (GWE).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!