A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A Handheld Quantifiable Soft Tissue Manipulation Device for Tracking Real-Time Dispersive Force-Motion Patterns to Characterize Manual Therapy Treatment. | LitMetric

Objective: Low back pain (LBP) is one of the leading neuromusculoskeletal (NMSK) problems around the globe. Soft Tissue Manipulation (STM) is a force-based, non-invasive intervention used to clinically address NMSK pain conditions. Current STM practice standards are mostly subjective, suggesting an urgent need for quantitative metrics. This research aims at developing a handheld, portable smart medical device for tracking real-time dispersive force-motions to characterize manual therapy treatments as Quantifiable Soft Tissue Manipulation (QSTM).

Methods: The device includes two 3D load-cells to quantify compressive and planar-shear forces, coupled with a 6 degrees-of-freedom IMU sensor for acquiring volitionally adapted therapeutic motions while scanning and mobilizing myofascial restrictions over larger areas of the body. These force-motions characterize QSTM with treatment parameters (targeted force, application angle, rate, direction, motion pattern, time) as a part of post-processing on a PC software (Q-Ware). A human case study was conducted to treat LBP as proof-of-concept for the device's clinical usability.

Results: External validation of treatment parameters reported adequate device precision required for clinical use. The case study findings revealed identifiable therapeutic force-motion patterns within treatments indicating subject's elevated force-endurance with self-reported pain reduction.

Conclusion: QSTM metrics may enable study of STM dosing for optimized pain reduction and functional outcomes using documentable manual therapy. Clinical trials will further determine its reliability and comparison to conventional STM.

Significance: This medical device technology not only advances the state-of-the-art manual therapy with precision rehabilitation but also augments practice with reproducibility to examine neurobiological responses of individualized STM prescriptions for NMSK pathology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10173803PMC
http://dx.doi.org/10.1109/TBME.2022.3222124DOI Listing

Publication Analysis

Top Keywords

manual therapy
16
soft tissue
12
tissue manipulation
12
quantifiable soft
8
device tracking
8
tracking real-time
8
real-time dispersive
8
force-motion patterns
8
characterize manual
8
medical device
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!