A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide-Neck Aneurysms - SCENT: 3-year outcomes. | LitMetric

Background: To report the 3-year safety and effectiveness of the Surpass Streamline flow diverter in the SCENT trial (Surpass Intracranial Aneurysm Embolization System Pivotal Trial to Treat Large or Giant Wide-Neck Aneurysms).

Methods: The Surpass Streamline flow diverter device was evaluated in a multicenter, prospective, single-arm, non-randomized interventional trial including patients with uncoilable or previously treated but failed aneurysms of the intracranial internal carotid artery. 3-year outcomes were tabulated with descriptive statistics and compared with 1-year outcomes.

Results: Of 180 patients in the modified intent-to-treat (mITT) cohort, 36-month clinical and angiographic follow-up was available in 134 and 117 cases, respectively. Effectiveness endpoint of complete aneurysm occlusion without clinically significant stenosis or retreatment was met in 71.8% (79/110, 95% CI 62.4% to 80.0%) of cases. Safety composite endpoint was 12.2% (22/180) over the 3-year period, with two major safety events (ipsilateral ischemic strokes) occurring between 12-36 months. Complete aneurysm occlusion was noted in 77.8% (91/117), and 99.1% (116/117) of the patients demonstrated adequate aneurysm occlusion (complete occlusion or neck residual). There were four cases (2.2%) of aneurysm rupture, all occurring within the first month of the index procedure. Target aneurysm retreatment rate was 2.8% (5/180).

Conclusion: The present findings support the long-term safety and effectiveness of the Surpass Streamline flow diverter device.

Trial Registration: NCT01716117.

Download full-text PDF

Source
http://dx.doi.org/10.1136/jnis-2022-019512DOI Listing

Publication Analysis

Top Keywords

surpass streamline
12
streamline flow
12
flow diverter
12
aneurysm occlusion
12
surpass intracranial
8
intracranial aneurysm
8
aneurysm embolization
8
embolization system
8
system pivotal
8
pivotal trial
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!