Introduction: The currently licensed quadrivalent MenACWY-CRM conjugate vaccine presentation consists of two vials (lyophilized MenA and liquid MenCWY) to be reconstituted before injection. A new fully liquid, single-vial formulation has been developed to simplify administration and prevent reconstitution errors. We present pooled safety data from two randomized, controlled, observer-blind phase 2b clinical trials, in which the fully liquid presentation was compared with the licensed presentation.
Methods: This is a post hoc analysis of two studies, in which safety data from participants aged 10-40 years who received one dose of either liquid MenACWY-CRM (1337 participants; MenACWY liquid group) or licensed MenACWY-CRM (1332 participants; MenACWY licensed group) were pooled. Frequencies were calculated for solicited adverse events (AEs) during 7 days post-vaccination and unsolicited AEs, including medically attended AEs and serious AEs (SAEs), during the 6-month safety follow-up period. Analysis results are presented by vaccine group, overall and by age category (10-17 and 18-40 years).
Results: Overall, AEs solicited for collection during the first 7 days after vaccination were reported by similar percentages of participants (69.2%, MenACWY liquid; 68.2%, MenACWY licensed), and were generally mild/moderate in intensity. Solicited local AEs were reported by 46.0% of the MenACWY liquid group and 43.5% of the MenACWY licensed group and solicited systemic AEs by 55.2 and 54.1%, respectively. During the 6-month post-vaccination period, unsolicited AEs were reported by 32.2 and 31.2% of the MenACWY liquid group and MenACWY licensed group, respectively, and medically attended AEs by 18.6 and 17.3%, respectively. Overall, 14 participants in each group (1.0 and 1.1%, respectively) reported SAEs, none of which was considered vaccine-related by the investigator. The safety profiles of both MenACWY-CRM presentations were similar for each age group and overall.
Conclusions: This pooled analysis shows the safety profile of fully liquid MenACWY-CRM is comparable with that of the currently licensed vaccine presentation.
Clinical Trial Registration: ClinicalTrials.gov Identifiers: NCT03652610 (August 29, 2018), NCT03433482 (14 February 2018).
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9829640 | PMC |
http://dx.doi.org/10.1007/s40264-022-01242-8 | DOI Listing |
Lab Chip
January 2025
School of Biomedical Engineering, Tsinghua University, Haidian District, Beijing 100084, China.
Rapid and accurate molecular diagnostics are crucial for preventing the global spread of emerging infectious diseases. However, the current gold standard for nucleic acid detection, reverse transcription polymerase chain reaction (RT-PCR), relies heavily on traditional magnetic beads or silica membranes for nucleic acid extraction, resulting in several limitations, including time-consuming processes, the need for trained personnel, and complex equipment. Therefore, there is an urgent need for fully integrated nucleic acid detection technologies that are simple to operate, rapid, and highly sensitive to meet unmet clinical needs.
View Article and Find Full Text PDFSmall
January 2025
Department of Chemical Engineering, Toronto Metropolitan University, 350 Victoria Street, Toronto, ON, M5B 2K3, Canada.
Research into flexible solid-state supercapacitors for wearable electronics focuses on achieving high performance and safety. Gel polymer electrolytes (GPEs) are preferred over fully solid-state electrolytes due to their better ionic conductivity while addressing safety concerns associated with liquid electrolytes. This study aims to enhance high-performance gel polymer electrolytes (HP-GPEs) by improving the ion transfer rate of polyvinyl alcohol (PVA) with sulfonated hexagonal boron nitride (known as white-graphene) and exploring how rheology influences ion-conduction within HP-GPEs.
View Article and Find Full Text PDFBiomed Chromatogr
February 2025
College of Pharmacy, Chongqing Medical University, Chongqing, China.
High-intensity focused ultrasound (HIFU) is a noninvasive soft tissue ablation technique, which utilizes ultrasound energy to induce thermal coagulation necrosis in targeted tissues. Whether this high energy causes side effects in vivo, such as the formation of peptide bonds, has not been fully investigated. Glycylglycine is the simplest dipeptide and hence is often used as a model compound for peptide studies.
View Article and Find Full Text PDFAesthetic Plast Surg
January 2025
Chi.Pla Chirurgia Plastica private office, Via suor Maria Mazzarello 54, Catania, Italy.
Introduction: Non-surgical alternatives to rhinoplasty are gaining interest but, despite its popularity, research on the long-term psychological impact and post-rhinofiller patients' satisfaction is limited. This study evaluates patient-reported satisfaction and quality of life immediately after and 6 months post-non-surgical rhinoplasty using the FACE-Q questionnaire.
Patients And Methods: This prospective study was conducted from May 2023 to March 2024, involving 83 patients who underwent rhinofiller treatments for esthetic purposes.
Nat Commun
January 2025
Gilbert S. Omenn Department of Computational Medicine and Bioinformatics, University of Michigan, Ann Arbor, MI, USA.
Data-independent acquisition has become a widely used strategy for peptide and protein quantification in liquid chromatography-tandem mass spectrometry-based proteomics studies. The integration of ion mobility separation into data-independent acquisition analysis, such as the diaPASEF technology available on Bruker's timsTOF platform, further improves the quantification accuracy and protein depth achievable using data-independent acquisition. We introduce diaTracer, a spectrum-centric computational tool optimized for diaPASEF data.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!