Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/bjo-2022-321948 | DOI Listing |
Small Methods
January 2025
State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing, 210016, China.
Bionic adhesive materials with 3D complex micro/nanostructures have several advantages of low preload, strong adhesion, switchable adhesion, etc. As the primary high-precision fabrication method for such materials, lithography is inherently limited by its 2D processing capabilities. Achieving complex 3D morphologies typically requires auxiliary processes, such as dipping and double-sided separate UV exposures, which increase both the complexity and limitations of the fabrication process.
View Article and Find Full Text PDFJACC Case Rep
January 2025
Chinese Institutes for Medical Research and Anzhen Hospital, Capital Medical University, Beijing, China.
Although open repair remains the mainstream treatment for aortic arch dissection, its surgical complexity and perioperative complications are significant. We developed a novel stentgraft system for less-invasive endovascular aortic arch repair. We successfully performed a total percutaneous transfemoral endovascular repair of aortic arch dissection using a novel off-the-shelf endograft system.
View Article and Find Full Text PDFCardiovasc Diagn Ther
December 2024
Cardiovascular Center, St. Luke's International Hospital, Tokyo, Japan.
Right ventricular (RV) dysfunction after biventricular repair is critical in most adults with congenital heart disease (ACHD). Conventional 2D magnetic resonance imaging (MRI) measurement is considered as a 'gold standard' for RV evaluation; however, addition information on ACHD after biventricular repair is sometimes required. The reasons why adjunctive information is required is as follows: (I) to evaluate the severity of cardiac burden in symptomatic patients with normal RV size and ejection fraction (EF), (II) to determine the optimal timing of invasive treatments in asymptomatic ones, and (III) to detect proactively a potential cardiac burden leading to ventricular deterioration, from a fluid dynamics perspective.
View Article and Find Full Text PDFMaterials (Basel)
December 2024
Key Laboratory of New Technology for Construction of Cities in Mountain Area, School of Civil Engineering, Chongqing University, Chongqing 400045, China.
High-strength bolt connectors, known for their robust strength and ease of disassembly, are suitable not only for the construction of new steel-concrete composite beams but also for reinforcing existing composite or steel beams. Static push-out tests were performed on nine specimens to examine their shear behavior. The primary failure mode was observed at the steel-concrete interface, characterized by the tensile-shear failure of the bolt and localized crushing of the concrete beneath the bolt.
View Article and Find Full Text PDFMHC-I proteins present epitopic peptides to CD8+ T cells to elicit multifaceted adaptive immune responses. The affinity and avidity of interactions between peptide-MHC molecules and T-cell receptors (TCR) are fundamental parameters that contribute to the induction of activated or anergic T cell states. Here, we present a loadable system, VLP-Open HLA, featuring a virus-like particle (VLP) that can accommodate up to 60 loadable HLA (HLA - human leukocyte antigen) molecules.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!