A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Does the use of patient-specific instrumentation improve resource use in the operating room and outcome after total knee arthroplasty?-A multicenter study. | LitMetric

Patient-specific instrumentation (PSI) in total knee arthroplasty (TKA) has been introduced to reduce instruments and surgical time and to improve implant alignment. The aim of this study was to compare TKA with patient-specific and conventional instrumentation with regard to the use of resources in the operating room (OR), alignment and patient-reported outcome. A total of 139 TKA with PSI or conventional instrumentation were included in three centers. Economic variables of the surgery (number of instrument trays, setup and cut-sew-time), radiological alignment and patient reported outcomes (VAS Pain Scale, Oxford Knee Score, EQ-5D) were assessed after 6 weeks, 6 and 12 months. There was a significant reduction of instrument trays and of time in the OR in the PSI group. The reduction varied between the centers. With strict reorganization, more than 50% of the instrument trays could be reduced while using PSI. There were no significant differences in cut-sew-time, implant position, leg axis, pain and function. The use of PSI was associated with significantly less OR resources. However, the savings did not compensate the costs for this technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9651589PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0277464PLOS

Publication Analysis

Top Keywords

instrument trays
12
patient-specific instrumentation
8
operating room
8
outcome total
8
total knee
8
conventional instrumentation
8
psi
5
instrumentation improve
4
improve resource
4
resource operating
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!