A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Seismic collapse risk of RC-timber hybrid building with different energy dissipation connections considering NBCC 2020 hazard. | LitMetric

The 2020 National Building Code of Canada (NBCC) seismic hazard model (SHM) marks a comprehensive update over its predecessor (NBCC 2015). For different regions in Canada, this will have an impact on the design of new buildings and performance assessment of existing ones. In the present study, a recently developed hybrid building system with reinforced concrete (RC) moment-resisting frames and cross-laminated timber (CLT) infills is assessed for its seismic performance against the latest SHM. The six-story RC-CLT hybrid system, designed using the direct displacement-based method, is located in Vancouver, Canada. Along with very high seismicity, southwestern British Columbia is characterized by complex seismotectonics, consisting of subduction, shallow crustal, and in-slab faulting mechanisms. A hazard-consistent set of 40 ground motion pairs is selected from the PEER and KiK-net databases, and used to estimate the building's seismic performance. The effects of using steel slit dampers (associated with large hysteresis loops) and flag-shaped energy dissipators (associated with the recentering capability) are investigated. The results indicate that the hybrid system has good seismic performance with a probability of collapse of 2-3% at the 2475-year return period shaking intensity. The hybrid building with steel slit dampers exhibits a collapse margin ratio of 2.8, which increases to 3.5-3.6 when flag-shaped dissipators are used. The flag-shaped dissipators are found to significantly reduce the residual drift of the hybrid building. Additionally, the seismic performance of the hybrid building equipped with flag-shaped dissipators is found to improve marginally when the recentering ratio is increased.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9637624PMC
http://dx.doi.org/10.1186/s43065-022-00061-6DOI Listing

Publication Analysis

Top Keywords

hybrid building
20
seismic performance
16
flag-shaped dissipators
12
hybrid system
8
steel slit
8
slit dampers
8
hybrid
7
seismic
6
building
6
performance
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!