A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mediator Microbial Biosensor Analyzers for Rapid Determination of Surface Water Toxicity. | LitMetric

Microbial mediator biosensors for surface water toxicity determination make it possible to carry out an early assessment of the environmental object’s quality without time-consuming standard procedures based on standard test-organisms, and provide broad opportunities for receptor element modifying depending on the required operational parameters analyzer. Four microorganisms with broad substrate specificity and nine electron acceptors were used to form a receptor system for toxicity assessment. Ferrocene was the most effective mediator according to its high rate constant of interaction with the microorganisms (0.33 ± 0.01 dm3/(g × s) for yeast Saccharomyces cerevisiae). Biosensors were tested on samples containing four heavy metal ions (Cu2+, Zn2+, Pb2+, Cd2+), two phenols (phenol and p-nitrophenol), and three natural water samples. The «ferrocene- Escherichia coli» and «ferrocene-Paracoccus yeei, E. coli association» systems showed good operational stability with a relative standard deviation of 6.9 and 7.3% (14 measurements) and a reproducibility of 7 and 5.2% using copper (II) ions as a reference toxicant. Biosensor analysis with these systems was shown to highly correlate with the results of the standard method using Chlorella algae as a test object. Developed biosensors allow for a valuation of the polluted natural water’s impact on the ecosystem via an assessment of the influence on bacteria and yeast in the receptor system. The systems could be used in toxicological monitoring of natural waters.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9655160PMC
http://dx.doi.org/10.3390/s22218522DOI Listing

Publication Analysis

Top Keywords

surface water
8
water toxicity
8
receptor system
8
mediator microbial
4
microbial biosensor
4
biosensor analyzers
4
analyzers rapid
4
rapid determination
4
determination surface
4
toxicity microbial
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!