Contrast media are widely diffused in biomedical imaging, due to their relevance in the diagnosis of numerous disorders. However, the risk of adverse reactions, the concern of potential damage to sensitive organs, and the recently described brain deposition of gadolinium salts, limit the use of contrast media in clinical practice. In recent years, the application of artificial intelligence (AI) techniques to biomedical imaging has led to the development of 'virtual' and 'augmented' contrasts. The idea behind these applications is to generate synthetic post-contrast images through AI computational modeling starting from the information available on other images acquired during the same scan. In these AI models, non-contrast images (virtual contrast) or low-dose post-contrast images (augmented contrast) are used as input data to generate synthetic post-contrast images, which are often undistinguishable from the native ones. In this review, we discuss the most recent advances of AI applications to biomedical imaging relative to synthetic contrast media.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9695136 | PMC |
http://dx.doi.org/10.3390/pharmaceutics14112378 | DOI Listing |
PLoS One
January 2025
Department of Structural Heart Disease, Cardiovascular Institute and Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.
Background: Assessing the endothelialization of occlusive devices noninvasively remains a challenge. Cardiac computed tomography angiography (CTA) can be employed to evaluate device endothelialization based on contrast uptake within the occluder.
Objective: This study examined device endothelialization using cardiac CTA and investigated the pathological associations.
J Cancer Res Ther
December 2024
Department of Interventional Ultrasound, Fifth Center of Chinese People's Liberation Army General Hospital, Beijing, China.
Objective: To examine the diagnostic efficacy of contrast-enhanced ultrasound (CEUS) with Sonazoid (Sonazoid-CEUS) for endometrial lesions.
Methods: In this prospective and multicenter study, data were collected from 84 patients with endometrial lesions from 11 hospitals in China. All the patients received a conventional US and Sonazoid-CEUS examination.
Eur Radiol Exp
January 2025
Laboratory of Molecular Imaging, Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, China.
Background: We examined chronic gadolinium retention impact on gene expression in the mouse central nervous system (CNS) after injection of linear or macrocyclic gadolinium-based contrast agents (GBCAs).
Methods: From 05/2022 to 07/2023, 36 female mice underwent weekly intraperitoneal injections of gadodiamide (2.5 mmol/kg, linear), gadobutrol (2.
Cureus
December 2024
Faculty of Medicine, King Khalid University, Abha, SAU.
Introduction Neck manipulations, including massages and self-cracking, are common practices, yet public awareness of their potential risks is poorly understood. This study explores public knowledge and awareness of the risks associated with neck manipulations in the Southern region of Saudi Arabia. Methods The study employed a descriptive cross-sectional design from May 2024 to July 2024, distributing a questionnaire to the adult population in the Southern Region.
View Article and Find Full Text PDFBMC Emerg Med
January 2025
Department of Emergency Medicine, Recep Tayyip Erdoğan University Training and Research Hospital, Rize, 53020, Turkey.
Background: The incidence of contrast-induced acute kidney injury (CI-AKI) in the general population ranges from 0.6 to 2.3%, whereas for specific high-risk patients, the incidence can reach more than 30-40%.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!