Composite resins with low flowability are usually handled and manipulated before insertion into the tooth preparation with gloved hands and/or using an instrument covered with a little amount of adhesive to facilitate modeling. We investigated if the modeling techniques (combined or not) affected physicochemical and esthetic properties of a composite resin. Specimens were fabricated and divided into groups according to the handling/modeling technique: Gloved-hands (composite was hand-manipulated with powdered latex gloves); Adhesive (adhesive was used in between the composite layers); Gloved-hands + Adhesive; Control (no adhesive and no touch with gloved-hands). The highest values for flexural strength (MPa), modulus of elasticity (GPa), and fracture toughness (MPa.m0.5) were obtained for Adhesive and Gloved-hands + Adhesive (p < 0.05); the lowest values were obtained for Control and Gloved-hands (p < 0.05). The Control group had the highest sorption. The Gloved-hands (p < 0.05) group had the highest solubility. Adhesive and Gloved-hands + Adhesive had a similar solubility (p > 0.05). The Control group (p < 0.05) had the lowest solubility. There was no statistical interaction between translucency vs. handling/modeling techniques and color stability vs. handling/modeling techniques. Adhesive as a modeling liquid protected the composite against sorption and solubility (if powdered gloves were used) and improved its physical/mechanical properties. Translucency and color stability were not correlated with modeling techniques.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9657255 | PMC |
http://dx.doi.org/10.3390/ma15217791 | DOI Listing |
J Wound Care
November 2024
OrthoGroup, Orthopedic Practice, Eidelstedter Platz 1, 22523, Hamburg, Germany.
Objective: Currently there is limited real-world research on the adhesion qualities, pain and clinical performance of specific silicone adhesives products, and their role in maintaining skin integrity and preventing medical adhesive-related skin injuries (MARSI). This paper presents a clinical evaluation of performance and safety parameters of two silicone adhesive dressings on lacerations or surgical wounds and the surrounding skin in daily practice on fragile skin.
Method: An observational, prospective, multicentre, uncontrolled post-market clinical observational study with Leukomed T skin sensitive and Leukomed T plus skin sensitive (both BSN medical GmbH, Essity Group) was undertaken at three sites across Germany between June 2021 to November 2022.
Materials (Basel)
November 2022
School of Dentistry, University Ceuma (UNICEUMA), R. Josué Montello, 1, Renascença II, São Luis 65075-120, Brazil.
Composite resins with low flowability are usually handled and manipulated before insertion into the tooth preparation with gloved hands and/or using an instrument covered with a little amount of adhesive to facilitate modeling. We investigated if the modeling techniques (combined or not) affected physicochemical and esthetic properties of a composite resin. Specimens were fabricated and divided into groups according to the handling/modeling technique: Gloved-hands (composite was hand-manipulated with powdered latex gloves); Adhesive (adhesive was used in between the composite layers); Gloved-hands + Adhesive; Control (no adhesive and no touch with gloved-hands).
View Article and Find Full Text PDFSimultaneously with the introduction of new surgical gloves with heavily powdered outside surfaces, complications repeatedly occurred after laparotomies. Four patients were compelled to undergo a second operation, during which peritoneal fibrous adhesions and foreign body granulomas of omentum were found. After resection of the omentum, healing proceeded without disturbance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!