(1) Background: The paper addresses the effect of carbon fibers (CFs) treatment by low-temperature plasma with runaway electrons on the deformation behavior of the polyetheretherketone (PEEK)-layered composites. (2) Methods: The effect of the interlayer adhesion on the mechanical response of the composites was assessed through the tensile and three-point bending tests. In addition, computer simulations of the three-point bending were carried out with the use of the finite element analysis (FEM) with varying conditions at the "PEEK-CF layers" interface. (3) Results: DRE-plasma treatment during the optimal time of t = 15 min led to formation of a rougher surface and partial desizing of a finishing agent. The shear strength of the layered composites increased by 54%, while the tensile strength and the flexural modulus (at three-point bending) increased by 16% (up to 893 MPa) and by 10% (up to 93 GPa), respectively. (4) Conclusions: The results of the numerical experiments showed that the increase in the stiffness, on the one hand, gave rise to enlarging the flexural modulus; on the other hand, a nonlinear decrease in the strength may occur. For this reason, the intention to maximize the level of the interlayer stiffness can result in lowering the fracture toughness, for example, at manufacturing high-strength composites.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9654359 | PMC |
http://dx.doi.org/10.3390/ma15217625 | DOI Listing |
J Funct Biomater
January 2025
Institute of Oral Science, Chung Shan Medical University, Taichung City 402, Taiwan.
Environmental protection issues have received widespread attention, making material recycling increasingly important. The upcycling of polysulfone (PSF) medical waste, recognized as a high-performance plastic with excellent mechanical properties, deserves promotion. While PSF is suitable for use as an orthopedic implant material, such as internal fixation, its osteogenesis capabilities must be enhanced.
View Article and Find Full Text PDFJ Dent
January 2025
University of Saskatchewan, College of Dentistry. 107 Wiggins Rd, Saskatoon, SK, Canada. S7N 5E5. Electronic address:
Bulk-fill, monochromatic, and ORMOCER composites were introduced in restorative dentistry with the aim of reducing clinical time and/or alleviating contraction stresses at the interface between the tooth and restoration. While the conversion and immediate properties of these materials are comparable to conventional composites, studies evaluating their long-term properties and the structure of the polymer matrix are lacking. The objective of this study was to evaluate the degree of conversion and, indirectly, the crosslink density of conventional, bulk-fill, monochromatic, and ORMOCER resin composites.
View Article and Find Full Text PDFScientificWorldJournal
January 2025
Department of Orthodontics, College of Dentistry, University of Baghdad, Baghdad, Iraq.
While polyethylene terephthalate glycol (PETG) is widely used in orthodontic appliances such as clear aligners and retainers, there is limited experimental data assessing its performance under functional stresses, such as those encountered during dental movements and palatal expansion. This study aims to evaluate the ability of PETG thermoplastic material to withstand deformation under functional and expansion forces, specifically within the context of orthodontic applications. To estimate the firmness of the screw within the appliance, a universal Instron testing machine was used to record the forces released by each activation of the expander within the upper part of 10 clear modified twin blocks (MTBs) made from PETG and compare it with that released by 10 conventional twin blocks (CTBs).
View Article and Find Full Text PDFACS Omega
January 2025
Integrated Manufacturing Technologies Research and Application Center, Sabanci University, Tuzla, Istanbul 34956, Turkey.
In this study, a thorough examination of the chemical, thermal, and mechanical characteristics, as well as shape memory behavior at low temperatures, of blends consisting of polylactic acid (PLA) and polyurethane (TPU) is conducted. The research involves the preparation of PLA/TPU mixtures with varying concentrations of TPU using a high-speed thermo-kinetic mixing approach. Chemical, morphological, and thermal analyses were conducted on pure PLA, TPU, and PLA/TPU mixtures by using Fourier Transform Infrared (FTIR), X-ray diffraction pattern spectroscopy (XRD), scanning electron microscopy (SEM), thermogravimetric analysis (TGA), differential scanning calorimetry (DSC), and dynamic mechanical analysis (DMA).
View Article and Find Full Text PDFACS Omega
January 2025
Department of Chemical and Biomedical Engineering, FAMU-FSU College of Engineering, Tallahassee, Florida 32310, United States.
Structural health monitoring (SHM) systems are critical in ensuring the safety of space exploration, as spacecraft and structures can experience detrimental stresses and strains. By deploying conventional strain gauges, SHM systems can promptly detect and assess localized strain behaviors in structures; however, these strain gauges are limited by low sensitivity (gauge factor, GF ∼ 2). This study introduces an approach to printing strain gauges with high sensitivity, while also considering stretchability and long-term durability.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!