The assessment of the knee alignment using standing weight-bearing full-leg radiographs (FLR) is a standardized method. Determining the load-bearing axis of the leg requires time-consuming manual measurements. The aim of this study is to develop and validate a novel algorithm based on artificial intelligence (AI) for the automated assessment of lower limb alignment. In the first stage, a customized mask-RCNN model was trained to automatically detect and segment anatomical structures and implants in FLR. In the second stage, four region-specific neural network models (adaptations of UNet) were trained to automatically place anatomical landmarks. In the final stage, this information was used to automatically determine five key lower limb alignment angles. For the validation dataset, weight-bearing, antero-posterior FLR were captured preoperatively and 3 months postoperatively. Preoperative images were measured by the operating orthopedic surgeon and an independent physician. Postoperative images were measured by the second rater only. The final validation dataset consisted of 95 preoperative and 105 postoperative FLR. The detection rate for the different angles ranged between 92.4% and 98.9%. Human vs. human inter-(ICCs: 0.85−0.99) and intra-rater (ICCs: 0.95−1.0) reliability analysis achieved significant agreement. The ICC-values of human vs. AI inter-rater reliability analysis ranged between 0.8 and 1.0 preoperatively and between 0.83 and 0.99 postoperatively (all p < 0.001). An independent and external validation of the proposed algorithm on pre- and postoperative FLR, with excellent reliability for human measurements, could be demonstrated. Hence, the algorithm might allow for the objective and time saving analysis of large datasets and support physicians in daily routine.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9689840 | PMC |
http://dx.doi.org/10.3390/diagnostics12112679 | DOI Listing |
J Osteopath Med
January 2025
McAllen Department of Trauma, South Texas Health System, McAllen, TX, USA.
Context: The injuries caused by falls-from-height (FFH) are a significant public health concern. FFH is one of the most common causes of polytrauma. The injuries persist to be significant adverse events and a challenge regarding injury severity assessment to identify patients at high risk upon admission.
View Article and Find Full Text PDFJ Vasc Bras
December 2024
Universidade Positivo - UP, Curitiba, PR, Brasil.
The lower limb is vascularized by the femoral artery, which continues as the popliteal artery. After the distal margin of the popliteus muscle, the popliteal artery divides into the anterior and posterior tibial arteries. Anatomical variations in the bifurcation of the popliteal artery are frequent.
View Article and Find Full Text PDFClin Interv Aging
December 2024
Department of Anesthesiology, The Affiliated Hospital of Yangzhou University, Yangzhou, 225012, People's Republic of China.
Purpose: Low density of electroencephalogram alpha band power was reported to be associated with perioperative cognitive dysfunction. Few studies have conducted to explore the effects of remimazolam on intraoperative frontal alpha band power spectrum density in older adults. Here, we aimed to explore the impact of remimazolam on intraoperative frontal brain wave alpha band activity and postoperative cognitive function in older adults undergoing lower extremity fractures surgeries.
View Article and Find Full Text PDFMembranoproliferative glomerulonephritis (MPGN) has previously been used as an umbrella term to describe a spectrum of hypocomplementemic glomerular diseases, which are rare causes of end stage kidney disease (ESKD). We present a 22-year-old man with a well-established medical history who had been complaining of 4 days of frothy dark urine, bilateral lower limb swelling, and puffiness on his face. For a month before his presentation, he had many bilateral skin lesions on his lower limbs that were leaking pus.
View Article and Find Full Text PDFPeerJ
January 2025
School of Sport and Exercise Sciences, Liverpool John Moores University, Liverpool, United Kingdom.
Background: Gait analysis is traditionally conducted using marker-based methods yet markerless motion capture is emerging as an alternative. Initial studies have begun to evaluate the reliability of markerless motion capture yet the evaluation of different clothing conditions across sessions and complete evaluation of the lower limb and pelvis reliability have yet to be considered. The aim of this study was to evaluate the inter-trial, inter-session and inter-session-clothing variation and root mean square differences between tight- or loose-fitting clothing during walking.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!