Ambient mass spectrometry imaging (MSI) methods come with the advantage of visualizing biomolecules from tissues with no or minimal sample preparation and operation under atmospheric-pressure conditions. Similar to all other MSI methodologies, however, ambient MSI modalities suffer from a pronounced bias toward either polar or nonpolar analytes due to the underlying desorption and ionization mechanisms of the ion source. In this study, we present the design, construction, testing, and application of an in-capillary dielectric barrier discharge (DBD) module for post-ionization of neutrals desorbed by an ambient infrared matrix-assisted laser desorption/ionization (IR-MALDI) MSI source. We demonstrate that the DBD device enhances signal intensities of nonpolar compounds by up to 10 compared to IR-MALDI without affecting transmission of IR-MALDI ions. This allows performing MSI experiments of mouse tissue and caterpillar tissue sections, visualizing the distribution of sterols, fatty acids, monoglycerides, and diglycerides that are not detected in IR-MALDI MSI experiments. The pronounced signal enhancement due to IR-MALDI-DBD compared to IR-MALDI MSI enables mapping of nonpolar analytes with pixel resolutions down to 20 μm in mouse brain tissue and to discern the spatial distribution of sterol lipids characteristic for histological regions of .

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9685590PMC
http://dx.doi.org/10.1021/acs.analchem.2c03247DOI Listing

Publication Analysis

Top Keywords

ir-maldi msi
12
mass spectrometry
8
spectrometry imaging
8
nonpolar analytes
8
compared ir-maldi
8
msi experiments
8
msi
7
ir-maldi
6
ir-maldi mass
4
imaging plasma
4

Similar Publications

Ambient mass spectrometry imaging (MSI) methods come with the advantage of visualizing biomolecules from tissues with no or minimal sample preparation and operation under atmospheric-pressure conditions. Similar to all other MSI methodologies, however, ambient MSI modalities suffer from a pronounced bias toward either polar or nonpolar analytes due to the underlying desorption and ionization mechanisms of the ion source. In this study, we present the design, construction, testing, and application of an in-capillary dielectric barrier discharge (DBD) module for post-ionization of neutrals desorbed by an ambient infrared matrix-assisted laser desorption/ionization (IR-MALDI) MSI source.

View Article and Find Full Text PDF

Ultraviolet matrix-assisted laser desorption ionization mass spectrometry imaging (UV-MALDI-MSI) is a powerful tool to visualize bacterial metabolites in microbial colonies and in biofilms. However, a challenge for the method is the efficient extraction of analytes from deeper within the bacterial colonies and from the cytoplasm of individual cells during the matrix coating step. Here, we used a pulsed infrared (IR) laser of 2.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!