Photoacoustic imaging (PAI) is a promising technique to assess different constituents in tissue. In PAI, the propagating waves are low-amplitude, isotropic, and broadband. A common approach in PAI is the use of a single linear or curved piezoelectric transducer array to perform both PA and ultrasound imaging. These systems provide freedom, agility, and versatility for performing imaging, but have limited field of view (FOV) and directivity that degrade the final image quality. Capacitive micromachined ultrasonic transducers (CMUTs) have a great potential to be used for PAI since they provide larger bandwidth and better cost efficiency. In this study, to improve the FOV, resolution, and contrast, we propose a multiperspective PAI (MP-PAI) approach using multiple CMUTs on a flexible array with shared channels. The designed array was used to perform MP-PAI in an in vitro experiment using a plaque mimicking phantom where the images were compounded both incoherently and coherently. The MP-PAI approach showed a significant improvement in overall image quality. Using only three CMUTs led to about 20% increase in generalized-contrast-to-noise ratio (gCNR), 2-dB improvement in peak signal-to-noise ratio (PSNR), and double the structural coverage in comparison to a single CMUT setup. In numerical studies, the MP-PAI was thoroughly evaluated for both the coherent and incoherent compounding methods. The assessments showed that the image quality further improved for increased number of transducers and angular coverage. For 15 transducers, the improvement for resolution and contrast could be up to three times the amount in a single-perspective image. Nonetheless, the most prominent improvement of MP-PAI was its ability to resolve the structural information of the phantoms.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/TUFFC.2022.3220999 | DOI Listing |
Invest Radiol
January 2025
From the Departments of Radiology (J.F.H., S.Y.C., J.-P.G., J.S., P.N., S.B.R., T.M.G.), Biomedical Engineering (S.B.R., T.M.G.), Medical Physics (S.Y.C., S.B.R., T.M.G.), Medicine (S.B.R.), and Emergency Medicine (S.B.R.), University of Wisconsin-Madison, WI; and Department of Diagnostic and Interventional Radiology (J.F.H., J.-P.G.), University Hospital Würzburg, Würzburg, Germany.
Rationale And Objectives: Pulmonary magnetic resonance angiography (MRA) is an imaging method with proven utility for the exclusion of pulmonary embolism and avoids the need for ionizing radiation and iodinated contrast agents. High-relaxivity gadolinium-based contrast agents (GBCAs), such as gadopiclenol, can be used to reduce the required gadolinium dose for pulmonary MRA. The aim of this study was to compare the contrast enhancement performance of gadopiclenol with an established gadobenate dimeglumine-enhanced pulmonary MRA protocol.
View Article and Find Full Text PDFInvest Radiol
January 2025
From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).
Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.
View Article and Find Full Text PDFACS Nano
January 2025
Department of Mechanical Engineering, University of California at Riverside, Riverside, California 92521, United States.
Sensing light's polarization and wavefront direction enables surface curvature assessment, material identification, shadow differentiation, and improved image quality in turbid environments. Traditional polarization cameras utilize multiple sensor measurements per pixel and polarization-filtering optics, which result in reduced image resolution. We propose a nanophotonic pipeline that enables compressive sensing and reduces the sampling requirements with a low-refractive-index, self-assembled optical encoder.
View Article and Find Full Text PDFAnn Med
December 2025
Department of Joint and Sports Medicine, Zhongnan Hospital, Wuhan University, Wuhan, China.
As life expectancy among patients infected with the human immunodeficiency virus (HIV) increases, a growing number of complications have been observed. This population displays an elevated risk of ischemic necrosis of the femoral head in comparison to the general population, which may be attributed to HIV infection, antiretroviral medication use, and hormone application. Patients infected with the human immunodeficiency virus (HIV) who also have necrosis of the femoral head tend to present at an earlier age, with a rapid disease progression and a high incidence of bilateral onset.
View Article and Find Full Text PDFJAMA Otolaryngol Head Neck Surg
January 2025
Department of Otolaryngology-Head and Neck Surgery, Vanderbilt University Medical Center, Nashville, Tennessee.
Importance: Airway stenosis is a rare but debilitating disorder that significantly degrades the quality of life in affected patients. Treatments are primarily surgical, and disease management lacks established medical therapies. The North American Airway Collaborative held its third symposium at The Johns Hopkins Hospital in Baltimore, Maryland, on April 15, 2024, focused on strategies to advance the care of these patients.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!