Creatinine is an amino acid derived from creatine catabolism at different steps of the body's organs, and its detection is significant because levels out of normal values are linked to some diseases like kidney failure. Normal concentration levels of creatinine in blood are from 45 to 110 μM, while in urine, typical concentrations range between 3.3 to 27 mM, and in saliva from 8.8 and 26.5 μM. Nowadays, the creatinine detection is carried through different spectroscopic-colorimetric methods; however, the resulting values present errors due to high interferences, delayed analysis, and poor stability. Electrochemical sensors have been an alternative to creatinine detection, and the electrochemical methods have been adapted to detect in enzymatic and non-enzymatic sensors, the latter being more relevant in recent years. Nanomaterials have made creatinine sensors more stable, sensitive, and selective. This review presents recent advances in creatinine electrochemical sensors for advances in point-of-care (POC) sensing devices, comprising both a materials point of view and prototypes for advanced sensing. The effect of the metal, particle size, shape and other morphological and electronic characteristics of nanomaterials are discussed in terms of their impact on the effective detection of creatinine. In addition, the application of nanomaterials in POC devices is revised pointing to practical applications and looking for more straightforward and less expensive devices to manufacture.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9606732 | PMC |
http://dx.doi.org/10.1039/d2ra04479j | DOI Listing |
J Cyst Fibros
January 2025
Department of Microbiology and Immunology, Geisel School of Medicine at Dartmouth, Lebanon, NH, USA; Department of Epidemiology, Geisel School of Medicine at Dartmouth, Lebanon, NH, USA. Electronic address:
Background: Adult people with cystic fibrosis (PwCF) have a higher risk of end-stage kidney disease than the general population. The nature and mechanism of kidney disease in CF are unknown. This study quantifies urinary kidney injury markers and examines the hypothesis that neutrophil activation and lung infection are associated with early kidney injury in CF.
View Article and Find Full Text PDFLupus
January 2025
Mansoura Nephrology and Dialysis Unit, Mansoura University, Mansoura, Egypt.
Background: Endoplasmic reticulum stress with protein misfolding has been introduced as a key pathogenetic mechanism in lupus nephritis (LN). Pregnancy is thought to exaggerate proteostasis, which leads to the accumulation of potentially pathogenic misfolded proteins in the urine, serum, and placenta particularly in women with preeclampsia. The detection of misfolded proteins is made using Congo red stain, which is referred to as congophilia.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Cardiovascular Center, The First Hospital of Jilin University, Changchun, 130021, China.
New-onset atrial fibrillation (NOAF) is associated with increased morbidity and mortality. Despite identifying numerous factors contributing to NOAF, the underlying mechanisms remain uncertain. This study introduces the triglyceride-glucose index (TyG index) as a predictive indicator and establishes a clinical predictive model.
View Article and Find Full Text PDFLangmuir
January 2025
Dipartimento di Fisica e Chimica - Emilio Segré, Università degli Studi di Palermo, Viale delle Scienze ed. 18, 90128 Palermo, Italy.
Amyloid fibrils have recently emerged as promising building blocks for functional materials due to their exceptional physicochemical stability and adaptable properties. These protein-based structures can be functionalized to create hybrid materials with a diverse range of applications. Here we report a simple eco-friendly protocol for generating amyloid fibrils from hen egg white lysozyme decorated with gold nanoparticles that can self-assemble in a hydrogel.
View Article and Find Full Text PDFBJUI Compass
December 2024
Desai Sethi Urology Institute, Miller School of Medicine University of Miami Miami Florida USA.
Objectives: The objectives of this study are to compare the accuracy of warm ischemia times (WITs) derived by a surgical artificial intelligence (AI) software to those documented in surgeon operative reports during partial nephrectomy procedures and to assess the potential of this technology in evaluating postoperative renal function.
Patients And Methods: A surgical AI software (Theator Inc., Palo Alto, CA) was used to capture and analyse videos of partial nephrectomies performed between October 2023 and April 2024.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!