Background: To assess the variability in wavefront aberrations with short-term wear of photochromic senofilcon A contact lenses in both its activated and inactive states.

Methods And Material: In this cross-sectional study, 20 participants who had previously used soft contact lenses were enrolled. Corneal aberrometry measurements were performed on each subject, without contact lenses, using Sirius Scheimpflug-Placido topography. The photochromic lenses were illuminated using a blue-violet light (  = 420 nm) so as to provoke an activated state, and measurements were taken with the lenses inserted, in both states. The root mean square (RMS) of the aberrations was calculated, and the higher- and lower-order aberrations, astigmatism, coma, spherical aberration, and trefoil measurements were evaluated using a 5.0-mm pupil diameter.

Results: The average contact lens sphere power was - 2.33 ± 1.07 D. The mean refractive errors with contact lens wear were 0.07 ± 0.18 D for the sphere and - 0.26 ± 0.15 D for the cylinder. The mean RMS values for all the corneal aberrations showed no statistically significant differences with and without contact lenses (p > 0.05). In a bivariate correlation analysis, there was a positive correlation between contact lens sphere power and coma (vertical and horizontal) in the activated state (r = 0.455, p = 0.44 and r = 0.495, p = 0.27, respectively).

Conclusion: The photochromic contact lenses did not influence ocular aberration during short-term wear, even when the photochromatic additive was activated. This property may help to provide more comfortable vision with lens wear. This finding needs to be verified by further studies.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-1973-8904DOI Listing

Publication Analysis

Top Keywords

contact lenses
20
contact lens
16
short-term wear
12
contact
9
aberration short-term
8
photochromic contact
8
activated state
8
lens sphere
8
sphere power
8
lens wear
8

Similar Publications

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Importance: For myopia control to be beneficial, it would be important that the benefit of treatment (slowed eye growth) is not lost because of faster than normal growth (rebound) after discontinuing treatment.

Objective: To determine whether there is a loss of treatment effect (rebound) after discontinuing soft multifocal contact lenses in children with myopia.

Design, Setting, And Participants: The Bifocal Lenses in Nearsighted Kids 2 (BLINK2) cohort study involved children with myopia (aged 11-17 years at BLINK2 baseline) who completed the BLINK Study randomized clinical trial.

View Article and Find Full Text PDF

Aim: To report the clinical and therapeutic particularities of pediatric keratoconus (KC).

Methods: Retrospective study focusing on patients aged less than 18 years, presenting with KC and followed in a tertiary reference center in Sfax, Tunisia.

Results: Our study involved 38 eyes of 20 children.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!