Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objectives: Plasma Epstein-Barr Virus (EBV)-DNA is a well-established prognostic biomarker in nasopharyngeal carcinoma (NPC). Different methods for assessment include single-copy gene targeted, European Conformity (CE)-marked assays, which are mostly employed in non-endemic settings, vs multiple-copy gene targeted, in-house BamHI-W based assays, which currently represent the most widely used method for EBV-DNA quantification. To date, evidence concerning the commutability of these different assays is still limited.
Materials And Methods: From August 2016 to March 2018, 124 plasma and 124 whole blood (WB) samples from 93 NPC patients were collected at different time-points for each patient. EBV-DNA viral load was quantified in pre- (n = 12) and post-treatment (n = 9), follow-up (n = 53), and recurrent/metastatic (R/M) (n = 50) phase. For each sample, one in-house BamHI-W vs three different CE-marked plasma assays were compared; the performance of plasma vs WB matrix was also assessed. Quantitative agreement of EBV-DNA values was evaluated by linear correlation and Bland-Altman analysis.
Results: A statistically significant (p = 0.0001) agreement between all CE-marked and the BamHI-W assays was found using plasma matrix, regardless of clinical phase. The results obtained in copies/ml were comparable to those expressed in IU/ml. When using WB matrix, the number of positive detections increased in the post-treatment phase.
Conclusions: Our retrospective comparison supported an agreement between Plasma BamHI-W and CE-marked assays in measuring EBV-DNA for non-endemic NPC patients. There were no significant interferences from different measurement units (IU/ml vs copies/ml). Further evaluations are needed to better clarify the role of WB.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oraloncology.2022.106229 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!