With increasing energy use and outbreaks of respiratory infectious diseases (such as COVID-19) in buildings, there is a growing interest in creating healthy and energy-efficient indoor environments. A novel heating system named low-temperature radiant floor coupled with intermittent stratum ventilation (LTR-ISV) is proposed in this study. Thermal performance, indoor air quality, energy and exergy performance were investigated and compared with conventional radiant floor heating (CRFH) and conventional radiant floor heating with mixing ventilation (CRFH + MV). The results indicated that LTR-ISV had a more uniform operative temperature distribution and overall thermal sensation, and air mixing was enhanced without generating additional draft sensation. Compared with CRFH and CRFH + MV, the indoor CO concentration in LTR-ISV can be reduced by 1355 ppm and 400 ppm, respectively. Airborne transmission risk can also be reduced by 5.35 times. The coefficient of performance for CRFH, CRFH + MV, and LTR-ISV during working hours was 4.2, 2.5, and 3.4, respectively. The lower value of LTR-ISV was due to the high energy usage of the primary air handing unit. In the non-working hours, LTR-ISV was 0.6 and 1.3 higher compared to CRFH and CRFH + MV, respectively. The exergy efficiency of LTR-ISV, CRFH, and CRFH + MV was 81.77 %, 76.43 %, and 64.71 %, respectively. Therefore, the LTR-ISV system can meet the requirements of high indoor air quality and thermal comfort and provides a reference for the energy-saving use of low-grade energy in space heating.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9630304 | PMC |
http://dx.doi.org/10.1016/j.enbuild.2022.112623 | DOI Listing |
Sci Rep
September 2024
Liaoshen Industries Group CO., LTD, China North Industries Group Corporation, Shenyang, 110045, Liaoning, China.
The mismatch between solar radiation resources and building heating demand on a seasonal scale makes cross-seasonal heat storage a crucial technology, especially for plateau areas. Utilizing phase change materials with high energy density and stable heat output effectively improves energy storage efficiency. This study integrates cascaded phase change with a cross-seasonal heat storage system aimed at achieving low-carbon heating.
View Article and Find Full Text PDFAlzheimers Res Ther
January 2024
Linus Health, Inc., 280 Summer Street, 10th Floor, Boston, MA, 02210, USA.
Background: Disease-modifying treatments for Alzheimer's disease highlight the need for early detection of cognitive decline. However, at present, most primary care providers do not perform routine cognitive testing, in part due to a lack of access to practical cognitive assessments, as well as time and resources to administer and interpret the tests. Brief and sensitive digital cognitive assessments, such as the Digital Clock and Recall (DCR™), have the potential to address this need.
View Article and Find Full Text PDFJ Craniofac Surg
October 2024
Department of Plastic and Reconstructive Surgery.
One of the greatest challenges in orbital reconstruction is to obtain adequate orbital volume and globe projection after traumatic injury. Autologous bone graft has been considered the gold standard for orbital floor reconstruction, but the harvesting yields many possible complications, such as donor site morbidity. Bone resorption is a frequent problem that can lead to insufficient volume after graft placement.
View Article and Find Full Text PDFMedicina (Kaunas)
July 2023
Laboratory of Biomechanics & Ergonomics, Department of Physiotherapy, Faculty of Health Sciences, International Hellenic University, Alexander Campus, P.O. Box 141, 57400 Thessaloniki, Greece.
Chronic non-specific low back pain (CNSLBP) is defined as back pain that lasts longer than 12 weeks. Capacitive and resistive electric transfer (TECAR) therapy utilizes radiant energy to generate endogenous heat and is widely used for the treatment of chronic musculoskeletal pain. The aim of this study was to investigate the efficacy of manual therapy (MT) program combined with TECAR therapy in individuals with CNSLBP.
View Article and Find Full Text PDFHeliyon
March 2023
School of Architecture, Soochow University, Suzhou, China.
The performance of a confined conference room under radiant heat floor combined with down-supply ventilation (RFDS) is investigated. The purpose of the study is to reveal the mechanism of indoor contaminants transmission from infected person and to protect the occupants. The exhaled contaminant dispersion was simulated using a CFD model and experimentally validated in an office with the down-supply ventilation (DS).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!