A low interfacial contact resistance is a challenge in polymer nanocomposites based on conductive nanomaterials for high-performance wearable electrode applications. Herein, a polydimethylsiloxane (PDMS)-based flexible nanocomposite incorporating high-conductivity 1D single-walled carbon nanotubes (SWCNTs) and 2D reduced graphene oxide (r-GO) was developed for high-performance electrocardiogram (ECG) wearable electrodes. A PDMS-SWCNT (P-SW; type I) nanocomposite containing only SWCNTs (2 wt%), exhibited rough and non-uniform surface morphology owing to the strong bundling effect of as-grown SWCNTs and randomly entangled aggregate structures and because of inefficient vacuum degassing (, = 1871 Ω). In contrast, owing to the hybrid structure of the SWCNTs (1 wt%) and r-GO (1 wt%), the PDMS-SWCNTs/r-GO (P-SW/r-GO; type II) nanocomposite exhibited uniform surface characteristics and low contact resistance (, = 63 Ω) through the formation of hybrid and long conducting pathways. The optimized nanocomposite (P-SW/r-GO/f; type III) possessed a fabric-assisted structure that enabled tunable and efficient vacuum degassing and curing conditions. Additionally, a long and wide conducting pathway was formed through more uniform and dense interconnected structures, and the contact resistance was drastically reduced (, = 15 Ω). The performance of the electrodes fabricated using the optimized nanocomposites was the same or higher than that of commercial Ag/AgCl gel electrodes during real-time measurement for ECG Bluetooth monitoring. The developed high-performance hybrid conducting polymer electrodes are expected to contribute significantly to the expansion of the application scope of wearable electronic devices and wireless personal health monitoring systems.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9595188 | PMC |
http://dx.doi.org/10.1039/d2na00220e | DOI Listing |
Cardiovasc Diabetol
January 2025
Department of Cardiology, the First Affiliated Hospital, Sun Yat-Sen University, 58 Zhongshan 2nd Road, Guangzhou, 510080, China.
Background: Triglyceride-glucose-BMI (TyG-BMI) index is a surrogate marker of insulin resistance and an important predictor of cardiovascular disease. However, the predictive value of TyG-BMI index in the progression of non-severe aortic stenosis (AS) is still unclear.
Methods: The present retrospective observational study was conducted using patient data from Aortic valve diseases RISk facTOr assessmenT andprognosis modeL construction (ARISTOTLE).
Epilepsy Res
January 2025
Epilepsy Program, Division of Neurology, Department of Pediatrics, Hospital for Sick Children, University of Toronto, Toronto, Ontario, Canada. Electronic address:
Background: Direct cortical electrical stimulation remains the gold standard for delineation of the primary motor cortex in patients with drug-resistant epilepsy (DRE) undergoing epilepsy surgery evaluation OBJECTIVE: This study aimed to explore the efficacy and safety of functional motor mapping through Stereo-EEG (SEEG) electrode contacts in children with DRE at our institute.
Methods: We performed a retrospective analysis of children who underwent SEEG evaluation and functional cortical mapping via bipolar electrical stimulation at our institution between July 2020 and June 2024. Detailed clinical, radiological and neurophysiological variable were extracted; qualitative and quantitative variables were summarized using appropriate descriptive statistics.
J Vis Exp
January 2025
Charlottetown Research and Development Center, Agriculture and Agri-Food Canada; Department of Chemistry, University of Prince Edward Island;
The iChip isolation technique uses an in-situ isolation device that increases the cultivability of previously unculturable microorganisms. Microorganisms are an important source of novel chemistries and potentially bioactive molecules. However, only 1% of environmental microorganisms can be cultured using conventional laboratory methods.
View Article and Find Full Text PDFACS Nano
January 2025
IBM Research Europe - Zurich, 8803 Rüschlikon, Switzerland.
Devices with a highly nonlinear resistance-voltage relationship are candidates for neuromorphic computing, which can be achieved by highly temperature dependent processes like ion migration. To explore the thermal properties of such devices, Scanning Thermal Microscopy (SThM) can be employed. However, due to the nonlinearity, the high resolution and quantitative method of AC-modulated SThM cannot readily be used.
View Article and Find Full Text PDFBeilstein J Nanotechnol
January 2025
Institut für Physik, Universität Osnabrück, Barbarastraße 7, 49076 Osnabrück, Germany.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!