With the increase in Natural Orifice Transluminal Endoscopic Surgery procedures, there is an increasing demand for surgical instruments with additional degrees of freedom, able to travel along tortuous pathways and guarantee dexterity and high accuracy without compromising the surrounding environment. The implementation of follow-the-leader motion in surgical instruments allows propagating the decided shape through its body and moving through curved paths avoiding sensitive areas. Due to the limited operational area and therefore the instrument size, the steerable shaft of these instruments is usually driven by cables that are externally actuated. However, a large number of degrees of freedom requires a great number of actuators, increasing the system complexity. Therefore, our goal was to design a new memory system able to impose a follow-the-leader motion to the steerable shaft of a medical instrument without using actuators. We present a memory mechanism to control and guide the cable displacements of a cable-driven shaft able to move along a multi-curved path. The memory mechanism is based on a programmable physical track with a mechanical interlocking system. The memory system, called MemoBox, was manufactured as a proof-of-concept demonstration model, measuring 70 mm × 64 mm × 6 mm with 11 programmable elements and featuring a minimum resolution of 1 mm. The prototype shows the ability to generate and shift complex 2D pathways in real-time controlled by the user.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9632848 | PMC |
http://dx.doi.org/10.3389/fmedt.2022.938643 | DOI Listing |
J Esthet Restor Dent
January 2025
Analysis of Techniques, Material and Instruments Applied to Digital Dentistry and CAD/CAM Procedures Research Group, Complutense University of Madrid, Madrid, Spain.
Objective: This case report presents the interdisciplinary retreatment of a patient with a worn full-mouth rehabilitation using defect-oriented restorations, horizontal preparations, and vertical dimension of occlusion (VDO) increase.
Clinical Considerations: A 58-year-old woman with a previous full-mouth rehabilitation presented with worn dentition, loss of VDO, and reduced posterior support. Examination revealed signs of parafunctional habits, tetracycline-stained teeth, and compromised aesthetics with exposed discolored teeth and open embrasure spaces.
Res Nurs Health
January 2025
Nursing Department, Universitat Rovira i Virgili, Tarragona, Spain.
The patient activation measure (PAM), a recognized measure of how active patients are in their care, is one of the most extensively used, widely translated, and tested instruments worldwide in measuring patient activation. This study aimed to assess the psychometric properties and construct validity of the Italian version of the 13-item Patient Activation Measure (PAM13-I) among patients undergoing elective laparoscopic cholecystectomy. A multicenter study was conducted across 111 surgical units in Italy.
View Article and Find Full Text PDFActa Neurochir (Wien)
January 2025
Division of Pediatric Neurosurgery, Department of Neurosurgery, Cincinnati Children's Hospital Medical Center, University of Cincinnati College of Medicine, Cincinnati, OH, USA.
Up to 40% of intracranial aneurysms arise from the anterior cerebral artery and anterior communicating artery (ACA-ACoA) complex. The vast variability of vessel anomalies and the surrounding critical structures correlate with severe morbidity and mortality rates in case of rupture. In the era of cutting-edge advantages of endovascular procedures, surgical expertise is reducing.
View Article and Find Full Text PDFMil Med
January 2025
Graduate School of Nursing, Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA.
Introduction: The storage of reusable medical devices (RMDs) is the final reprocessing phase and the step that directly precedes point-of-care delivery. Reusable medical devices, including surgical tools necessitating sterilization and semicritical devices such as endoscopes, undergo high-level disinfection. The rigorous reprocessing protocols and subsequent storage of RMDs are crucial in preserving their sterility and asepsis.
View Article and Find Full Text PDFInt J Med Robot
February 2025
Shenyang Jianzhu University, Shenyang, China.
Background: A surgical robot with force feedback can guarantee precise and gentle manipulation for endometrial repair, ensuring the effectiveness and safety of the manipulation. However, the design of force sensors for surgical robots is challenging due to the limited anatomical space and the requirement for continuous rotation.
Methods: This paper presents a novel force-sensing surgical instrument for endometrial repair, including an inner scraping instrument and an outer force sensing sheath.