A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Normal Values of Distal Radioulnar Joint Kinematics during a Dynamic Press Test. | LitMetric

 Measurement of in vivo distal radioulnar joint (DRUJ) pathomechanics during simple activities can represent the disability experienced by patients and may be useful in diagnostics of DRUJ instability. A first step is to describe the physiological normal limits for DRUJ kinematics in a reproducible and precise test setup, which was the aim of this study.  DRUJ kinematics were evaluated in 33 participants with dynamic radiostereometry (RSA) while performing a standardized press test examination. AutoRSA software was used for image analyses. Computed tomography (CT) forearm bone models were generated, and standardized anatomical axes were applied to estimate kinematic outcomes including, DRUJ translation, DRUJ position ratio, and changes in ulnar variance. Repeatability of dynamic RSA press test double examinations was evaluated to estimate the precision and intraclass correlation coefficient (ICC) test-retest agreement.  The maximum force during the press test was 6.0 kg (95% confidence interval [CI]: 5.1-6.9), which resulted in 4.7 mm (95% CI: 4.2-5.1) DRUJ translation, DRUJ position ratio of 0.40 (95% CI: 0.33-0.44), and increase in ulnar variance of 1.1 mm (95% CI: 1.0-1.2). The mean maximum DRUJ translation leveled off after a 5 kg force application. The DRUJ translation ICC coefficient was 0.93 within a prediction interval of ± 0.53mm.  This clinical study demonstrates the normal values of DRUJ kinematics and reports excellent agreement and high precision of the press tests examination using an automated noninvasive dynamic RSA imaging method based on patient-specific CT bone models. The next step is the application of the method in patients with arthroscopic verified triangular fibrocartilage complex injuries.  This is a Level IV, case series study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9633146PMC
http://dx.doi.org/10.1055/s-0041-1740486DOI Listing

Publication Analysis

Top Keywords

press test
16
druj translation
16
druj
10
normal values
8
distal radioulnar
8
radioulnar joint
8
druj kinematics
8
bone models
8
translation druj
8
druj position
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!